+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

ABB Stotz-Kontakt 2CSR255163R1165 DS301CA-B16A/0.03 6kA 1P+N FI/LS switch

To compare
To favorites
SKU:840185
ABB Stotz-Kontakt 2CSR255163R1165 DS301CA-B16A/0.03 6kA 1P+N FI/LS switch
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
In stock
€44.15
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breakers (RCBOs) offer protection for people and property, as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. They ensure protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 10 mA to earth. As well as fault protection (protection against indirect contact), additional protection and fire protection. They meet the product standards IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21), DIN EN 62423 (VDE 0664-40). Areas of application are household, commercial and industrial applications. The compact design of the DS301C residual current circuit breaker is ideal for use in power distribution systems where space is limited. The series comes with 30mA residual current and a B or C tripping characteristic. Dedicated phase rails are available for the quick cross-wiring of several DS301C FI/LS.

PropertyValue
Tripping characteristic:B
Current:16 A
Fault current:0.03 A
Voltage:240 V
Frequency:50 Hz
Number of poles:1
TE:1
Fault current type:A
Installation depth:17.6 mm
Rated breaking capacity according to IEC 60947-2:6 kA
Degree of protection (IP):IP20
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:1
Flush-mounted installation:no
Type of voltage:AC
False tripping protection:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:6 kA
Rated breaking capacity Icn according to EN 61009-1:6 kA
Breaking characteristic:instantaneous
With locking device:no
Connectable conductor cross-section, single-wire:1.5 to 16 mm²
Connectable conductor cross-section, stranded:1.5 to 10 mm²
Features
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated breaking capacity according to IEC 60947-2
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles
IP protection)
Voltage type
TE
Degree of contamination
Overvoltage category