ABB Stotz-Kontakt 2CSR275189R1154 DS201MA-C15/0.03-110V 10kA 1P+N Type A FI/LS switch
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
In stock
€124.03
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breakers (RCBOs) offer protection for people and property, as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. They guarantee protection of single-phase circuits against overload and short-circuit currents, protection against sinusoidal, alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. As well as fault protection (protection against indirect contact), additional protection and fire protection. Areas of application are mainly in commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. The DS201 MA 110V series has no approval and is specifically designed for 110 V AC to 230 V AC applications. They meet the product standards IEC 61009-1, IEC 61009-2-1., The approvals are: CCC (CN), ABS (USA), DNV (DE), RINA (IT), RMRS (RU), Lloyds Register (GB)., Rated switching capacity according to IEC/EN 61009 Icn = 10 kA., RCBO DS201 MA 110V Type A is 1-pole protected (LS), 2-pole switching.

PropertyValue
Tripping characteristic:B
Current:15 A
Fault current:0.03 A
Voltage:240 V
Frequency:50/60 Hz
Number of poles:2
TE:2
Fault current type:A
Installation depth:35 mm
Rated breaking capacity according to IEC 60947-2:15 kA
Degree of protection (IP):IP2X
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:1
Flush-mounted installation:no
Type of voltage:AC
False tripping protection:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:10 kA
Rated breaking capacity Icn according to EN 61009-1:10 kA
Breaking characteristic:instantaneous
With locking device:no
Connectable conductor cross-section, single-wire:0.75 to 25 mm²
Connectable conductor cross-section, stranded:0.75 to 16 mm²
Features
Shutdown characteristics
Voltage
Flush-mounted installation
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated breaking capacity according to IEC 60947-2
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles
IP protection)
Voltage type
TE
Degree of contamination
Overvoltage category