ABB Stotz-Kontakt 2CTB803972R1400 OVR T2 1N 40-440 P TS QS surge arrester

To compare
To favorites
SKU:543065
ABB Stotz-Kontakt 2CTB803972R1400 OVR T2 1N 40-440 P TS QS surge arrester
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Protection level
With remote signaling contact
In stock
€177.81
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

SPD type 2 surge protection devices with QuickSafe® technology, tested in accordance with DIN EN 61643-11, are suitable for protecting low-voltage electrical systems and end devices from dangerous surges. The SPDs meet the surge protection requirements set out in DIN0100-443 and 534. All surge protection devices are compatible with the System pro M compact series and can be connected to these via phase rails. All devices are equipped with a function display. The versions with reserve varistor(s) offer additional protection for the electrical system in that the surge protection device is not completely disconnected from the mains at the end of its service life, but an additional varistor guarantees basic protection and the system is therefore still protected until the surge protection module is replaced.

PropertyValue
Protection level:1.5 kV
Nominal discharge current (8/20):20 kA
Maximum continuous voltage AC:440 V
Nominal voltage AC:230 V
Protection level LN:1.25 kV
Mounting type:DIN rail TH35
Size:2 TE
Signaling on the device:optical
With remote signaling contact:yes
Test class type 2:yes
Max. conductor cross-section flexible (fine-stranded):16 mm²
Max. Conductor cross-section rigid (single/multi-wire):25 mm²
Protection level N-PE:1.4 kV
Integrated backup fuse:no
Protection class (IP):IP20
Network type DC:no
Network type IT:no
Network type TN:yes
Network type TN-C:no
Network type TN-CS:yes
Network type TN-S:yes
Network type TT:yes
Network type other:no
Number of conductors (excluding earth):2
Short-circuit strength (Isccr):100 kA
Max. discharge current (8/20):80 kA
Features
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Protection level
With remote signaling contact
Number of conductors (excluding earth)
Network form TT
Network type TN-S
Max. discharge current (8/20)
Test class type 2
Network form TN
Network type TN-C
Network type TN-C-S
Short circuit strength (Isccr)
Protection level L-N
Network type DC
Protection level N-PE
Integrated backup fuse
Network type IT
HAB
Manufacturer
HAN
GTIN
Size
Highest continuous voltage AC
Mounting type
Nominal discharge current (8/20)
Nominal voltage AC
IP protection)
Signaling on the device
No reviews yet — your comment may be first.
All reviews 0
general rating