Description
Overvoltage protection devices OVR PV T1-T2 protect electrical systems against lightning surges. They are tested according to IEC 61643-31, DIN EN 50539-11 and UL 1449 Type 1+2. The status of the overvoltage protection device is shown via a mechanical function display. OVR with Telesignal TS are optionally equipped with a potential-free changeover contact and can report the status to a monitoring system, for example. The application is specifically on the DC side of photovoltaic systems.
Property | Value |
Protection level: | 5 kV |
Nominal discharge current (8/20): | 20 kA |
Maximum continuous voltage AC: | 1500 V |
Maximum continuous voltage DC: | 1500 V |
Nominal voltage DC: | 1500 V |
Protection level LN: | 5 kV |
Mounting type: | DIN rail TH35 |
Size: | 3 TE |
Signaling on Device: | without |
With remote signaling contact: | no |
Test class type 2: | yes |
Max. conductor cross-section flexible (fine-stranded): | 25 mm² |
Max. PV voltage: | 1500 V |
Max. Conductor cross-section rigid (single/multi-wire): | 35 mm² |
Protection level N-PE: | 5 kV |
Integrated backup fuse: | no |
Protection class (IP): | IP20 |
Network type DC: | yes |
Network type IT: | no |
Network type TN: | no |
Network type TN-C: | no |
Network type TN-CS: | no |
Network type TN-S: | no |
Network type TT: | no |
Network type other: | no |
Number of conductors (without earth): | 2 |
Short-circuit strength (Isccr): | 11 kA |
Max. discharge current (8/20): | 30 kA |
Max. overcurrent protection device branch wiring (fuse): | 10 A |
Integrated short-circuit protection: | no |
Leakage current free: | no |
Features
Max. conductor cross-section rigid (single/multi-wire)
35 mm²
Max. conductor cross-section flexible (fine-stranded)
25 mm²
Protection level
5 kV
With remote signaling contact
No
Highest continuous voltage DC
1500 V
Number of conductors (excluding earth)
2
Network form TT
No
Network type TN-S
No
Max. discharge current (8/20)
30 kA
Test class type 2
Yes
Network form TN
No
Network type TN-C
No
Nominal voltage DC
1500 V
Network type TN-C-S
No
Short circuit strength (Isccr)
11 kA
Protection level L-N
5 kV
Network type DC
Yes
Protection level N-PE
5 kV
Integrated backup fuse
No
Network type IT
No
HAB
OVR PV T1-T2 5-1.500 P QS PV SPD
Manufacturer
HAN
2CTB812050R1500
GTIN
4053546034646
Size
3 HP
Highest continuous voltage AC
1500V
Mounting type
DIN rail TH35
Nominal discharge current (8/20)
20kA
IP protection)
IP20
Signaling on the device
Without
Reviews
No reviews yet — your comment may be first.
All reviews 0