+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

ABB Stotz-Kontakt 2CTB812122R1000 OVR PV T1-T2 12.5-1.000 C QS PV SPD surge protection

To compare
To favorites
SKU:833345
ABB Stotz-Kontakt 2CTB812122R1000 OVR PV T1-T2 12.5-1.000 C QS PV SPD surge protection
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Protection level
With remote signaling contact
In stock
€92.28
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Replacement modules for surge protection device OVR PV T2 with function display. They are tested according to IEC 61643-31, DIN EN 50539-11 and UL 1449 5th Ed Type 2. The application is specifically on the DC side of photovoltaic systems.

PropertyValue
Protection level:3.8 kV
Nominal discharge current (8/20):20 kA
Maximum continuous voltage DC:1000 V
Nominal voltage DC:1000 V
Mounting type:DIN rail TH35
Size:3 TE
Signaling on the device:without
With remote signaling contact:no
Test class type 2:yes
Max. conductor cross-section flexible (fine-stranded):25 mm²
Max. PV voltage:1000 V
Max. Conductor cross-section rigid (single/multi-wire):35 mm²
Integrated backup fuse:no
Protection class (IP):IP20
DC network type:yes
IT network type:no
TN network type:no
TN network type:no
TN-C network type:no
TN-CS network type:no
TN-S network type:no
TT network type:no
TN network type other:no
Number of conductors (excluding earth):2
Short-circuit strength (Isccr):11 kA
Max. discharge current (8/20):40 kA
Max. overcurrent protection device branch wiring (fuse):10 A
Max. overcurrent protection device V-wiring (fuse):10 A
Integrated short-circuit protection:no
Leakage current free:no
Features
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Protection level
With remote signaling contact
Highest continuous voltage DC
Number of conductors (excluding earth)
Network form TT
Network type TN-S
Max. discharge current (8/20)
Test class type 2
Network form TN
Network type TN-C
Nominal voltage DC
Network type TN-C-S
Short circuit strength (Isccr)
Network type DC
Integrated backup fuse
Network type IT
HAB
Manufacturer
HAN
GTIN
Size
Mounting type
Nominal discharge current (8/20)
IP protection)
Signaling on the device