Description
Features
Reviews
Frequency converter ACH580-01-062A-4+B056380-480 V / Pn 30kW / In 62A / IP55 with EMC filter Cat. C2 public networks
| Property | Value |
| Protection class (IP): | IP55 |
| Mains frequency: | 50/60 Hz |
| Mains voltage: | 400 V |
| Number of other HW interfaces: | 15 |
| Number of serial HW interfaces RS-485: | 1 |
| Max. Output frequency: | 500 Hz |
| Use in industrial areas permitted: | yes |
| Height: | 600 mm |
| Width: | 203 mm |
| Depth: | 265 mm |
| Type of converter: | U-converter |
| Max. output power with linear load at rated output voltage: | 30 kW |
| Supports protocol for data highway: | no |
| 4-quadrant operation possible: | no |
| With optical interface: | no |
| Supports protocol for LON: | no |
| Relative symmetrical mains voltage tolerance: | 10 % |
| Supports protocol for AS-Interface Safety at Work: | no |
| Integrated brake chopper: | yes |
| Number of input phases: | 3 |
| Supports protocol for TCP/IP: | no |
| Supports protocol for DeviceNet: | no |
| Supports protocol for PROFINET IO: | no |
| Supports protocol for PROFIBUS: | no |
| Supports protocol for EtherNet/IP: | no |
| Supports protocol for INTERBUS-Safety: | no |
| Supports protocol for SUCONET: | no |
| Supports protocol for CAN: | no |
| Supports protocol for KNX: | no |
| Use in residential and commercial areas permitted: | yes |
| Supports protocol for INTERBUS: | no |
| Supports protocol for other bus systems: | no |
| Supports protocol for ASI: | no |
| Supports protocol for SafetyBUS p: | no |
| Supports protocol for MODBUS: | no |
| With control element: | yes |
| Supports protocol for PROFIsafe: | no |
| Supports protocol for DeviceNet Safety: | no |
| Relative symmetrical mains frequency tolerance: | 5 % |
| Supports protocol for SERCOS: | no |
| Number of output phases: | 3 |
| Supports protocol for PROFINET CBA: | no |
| Supports protocol for Foundation Fieldbus: | no |
| Max. delivered power at square. Load at rated output voltage: | 30 kW |
| Number of HW interfaces USB: | 1 |
| With PC connection: | yes |
| Nominal output current I2N: | 62 A |
| Max. output voltage: | 480 V |
| Supports protocol for BACnet: | no |
Features
Supports protocol for KNX
No
With control element
Yes
With optical interface
No
HAB
ACH580-01-062A-4+B
Manufacturer
HAN
3AUA0000083598
GTIN
6438177306290
Width
203 mm
Height
600 mm
Depth
265 mm
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No
No reviews yet — your comment may be first.
All reviews 0