The 3-pole AFZB contactors meet the latest standards for rolling stock and allow installation in passenger or driver's cabs of trains that frequently travel in tunnels or underpasses. They switch power circuits with motors, slightly inductive or non-inductive loads. They meet all the important standards for rolling stock: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of the EN 50155 standards, shock and vibration resistance according to IEC 61373 Cat. 1, Class B. They also achieve the highest levels of fire and smoke behavior while complying with the European standard EN 45545-2 (HL2 hazard levels) when mounted in groups. The contactors with coil code -21 enable direct control via 24V DC 500mA PLC outputs and require a very low holding power of only 1.7W. AFZB contactors can withstand short voltage dips and voltage drops (according to SEMI F47-0706). All integrated or subsequently attached auxiliary break contacts are designed as mirror contacts in accordance with IEC60947-5-1 Appendix L. They also have built-in overvoltage protection and do not require any additional suppression elements.
Property | Value |
Rated control supply voltage Us at AC 50 Hz: | 24 to 60 |
Rated control supply voltage Us at AC 60 Hz: | 24 to 60 |
Rated control supply voltage Us at DC: | 20 to 60 |
Type of voltage for actuation: | AC/DC |
Rated operating current Ie at AC-1, 400 V: | 30 |
Rated operating current Ie at AC-3, 400 V: | 18 |
Rated operating power at AC-3, 400 V: | 7.5 |
Suitable for series installation: | no |
Number of auxiliary contacts as normally closed contacts: | 1 |
Connection type main circuit: | Spring-loaded connection |
Number of normally open contacts as main contacts: | 3 |