ABB Stotz-Kontakt DDA203 B-63/0.3 AP-R, DDA203 B APR 63/0.3 FI-Block for S203 3P, all-current sensor, 63A, 300mA, 2CSB203592R3630
HAB
Manufacturer
HAN
GTIN
In stock
€657.23
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

DDA200 Type B AP-R for smooth DC residual currents, AC/DC sensitive, 10 ms short-time delayed, surge current resistant 3 kA, The FI block (RCU) is for customer-side assembly with automatic circuit breakers from the S200 series. The resulting FI/LS combinations (RCBOs) offer personal and property protection as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. They guarantee protection of 1P+N, 2P, 3P, 3P+N or 4P circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 10 mA to earth, as well as smooth DC residual currents in the frequency range of 0...1 kHz. As well as fault protection (protection against indirect contact), additional protection (with I n 30 mA) and fire protection (with I n 300 mA)., They meet the product standards IEC/EN 61009-1 (VDE 0664-20) Appendix G, IEC/EN 61009-2-1, DIN EN 62423 (VDE 0664-40). Areas of application are primarily commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks., Optimal compromise between safety and operational continuity offers high system availability, thanks to the interference immunity with surge current resistance (surge current form 8/20 s) = 3,000 A against unwanted triggering and 10 ms short-term delay.

PropertyValue
Max. Delay time:10 ms
Nominal voltage:230 to 400 V
Delay time adjustable:no
Rated residual current adjustable:no
Nominal current:63 A
Residual current type:B
Number of poles:3
Rated residual current:0.3 A
Surge current strength:3 kA
Frequency:50/60 Hz
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Connectable conductor cross-section, single-wire:25 mm²
Connectable conductor cross-section, stranded:25 mm²
False tripping protection:yes
With locking device:yes
Protection class (IP):IP2X
Ambient temperature during operation:-25 to 55 °C
Features
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Rated residual current
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
False trigger protection
Residual current type
Frequency
With locking device
Nominal voltage
Rated current
Number of poles
IP protection)
Surge current strength
Ambient temperature during operation