+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

ABB Stotz-Kontakt FI F204B25/0.03, residual current circuit breaker 4P, type B+, 25A, 30mA, short-time delay, 2CSF204701R1250

To compare
To favorites
SKU:201790
ABB Stotz-Kontakt FI F204B25/0.03, residual current circuit breaker 4P, type B+, 25A, 30mA, short-time delay, 2CSF204701R1250
HAB
Manufacturer
HAN
GTIN
In stock
€811.51
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

F200 Type B+ for smooth DC residual currents and advanced, preventive fire protection, AC/DC sensitive, 10 ms short-time delayed, surge current resistant 3 kA, residual current circuit breakers (RCCBs) offer personal and material protection as well as protection against electrically ignited fires in accordance with DIN0100-410 and DIN0100-530. The residual current circuit breakers of the F200 B+ series ensure protection against sinusoidal alternating currents, pulsating currents and smooth DC residual currents to earth. As well as fault protection (protection against indirect contact), additional protection (with I n 30 mA) and fire protection (with I n 300 mA). They meet the product standards for RCDs type A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and for type B+ DIN0664-400. Areas of application are mainly in commercial and industrial applications. The extensive range of accessories offers you everything you need for your installation tasks. The RCCB type B+ detect smooth DC residual currents, react earlier than the RCCB type B with max. 420 mA and have a frequency range of 0 ... 20 kHz for detecting the residual current. They therefore offer advanced, preventive fire protection (extended fire protection according to DIN0100-530) for e.g. fire-prone premises and commercial units.

PropertyValue
Rated voltage:400 V
Rated current:25 A
Rated residual current:30 mA
Mounting type:DIN rail
Protection class (IP):IP2X
Frequency:50 Hz
Number of poles:4
Width in pitch units:4
Selective type:no
Residual current type:B+
Additional equipment possible:yes
Installation depth:69 mm
Short-circuit strength (Icw):1 kA
Surge current strength:3 kA
Short-time delayed type:yes
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
With locking device:yes
Ambient temperature during Operating:-25 to 40 °C
Pollution level:2
Connectable conductor cross-section, stranded:0 to 25 mm²
Connectable conductor cross-section, single-wire:25 mm²
Features
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Residual current type
Frequency
Short circuit strength (Icw)
Short-time delayed type
With locking device
Mounting type
Number of poles
IP protection)
Selective type
Surge current strength
Ambient temperature during operation
Degree of contamination
Additional equipment possible
No reviews yet — your comment may be first.
All reviews 0
general rating