+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

ABB Stotz-Kontakt RD2, residual current relay 230-400VAC, 2CSM142120R1201

To compare
To favorites
SKU:203381
ABB Stotz-Kontakt RD2, residual current relay 230-400VAC, 2CSM142120R1201
Rated frequency
HAB
Manufacturer
HAN
In stock
€205.99
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current monitors (RCM) with an external transformer are suitable for detecting residual currents. The residual current sensitivity and response time can be set using mini-DIP switches. The residual current relays RD2, in conjunction with an external toroidal core transformer TR..., allow earth fault protection of cables and devices. They are designed for use in single- and three-phase networks with higher rated currents. The modular transformer TRM (transformer diameter 29 mm) is designed to be snapped onto the DIN rail, the remaining transformers TR (transformer diameter up to 110 mm) are designed to be screwed on. If an earth fault current (pulse current sensitive) occurs, the transformer transmits a signal to the residual current relay, which evaluates it and compares it with the set value. If the set value is exceeded, the output relay is switched after the set time and the red LED lights up. The sensitivity (residual currents) and response time of the relay can be set using mini-DIP switches. A changeover contact is available as an output. The connection between the relay and the converter is always checked. If this is interrupted, the relay switches after the set response time. The test button simulates a differential current. When this is pressed, the relay switches without delay, regardless of the response time set. The RD2 changes to the alarm status. The reset button sets the relay to its initial state.

PropertyValue
Rated voltage:400 V
Type of voltage for actuation:AC
Max. permissible response delay time:5 s
Design of the electrical connection:Screw connection
Min. adjustable response delay time:0.3 s
Response value current 1:2000 mA
Number of contacts as changeover contact:1
Rated frequency:50 to 60 Hz
Width:35 mm
Height:85 mm
Depth:65 mm
With removable terminals:no
Function:for alternating current networks
Display of the residual current:no
Fault storage possible:no
Rated control supply voltage Us at AC 50 Hz:400 V
Rated control supply voltage Us at AC 60 Hz:400 V
Features
Rated frequency
HAB
Manufacturer
HAN
GTIN
Number of contacts as changeover
Design of the electrical connection
Rated voltage
Rated control supply voltage Us at AC 50 Hz
Rated control supply voltage Us at AC 60 Hz
Width
Function
Height
With removable clamps
Voltage type for actuation
Depth
No reviews yet — your comment may be first.
All reviews 0
general rating