ABB Stotz-Kontakt S-ARC1 M B6, AFDD+LS S-ARC1M-B6, 10kA, 1P+N, 2TE arc fault protective device + LS, 2CSA275901R9065

To compare
To favorites
SKU:469961
ABB Stotz-Kontakt S-ARC1 M B6, AFDD+LS S-ARC1M-B6, 10kA, 1P+N, 2TE arc fault protective device + LS, 2CSA275901R9065
HAB
Manufacturer
HAN
GTIN
In stock
€170.66
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Arc fault protective device (AFDD) with automatic circuit breaker (MCB) according to IEC/EN 62606 (VDE 0665-10) and IEC/EN 60898-1 (VDE 0641-11) offer protection against serial and parallel arc faults, protection against overcurrent (overload or short circuit), protection against overvoltage (only for AFDD internal) and protection against electrically ignited fires according to DIN0100-420. , Mandatory areas of application according to DIN01000 are in single-phase alternating current systems with In 16 A in bedrooms or common rooms in homes and day care centers for children, disabled or elderly people or in barrier-free apartments as well as in rooms or places with a fire risk (with a particular fire risk, fire-prone premises), predominantly/mainly made of flammable building materials (the classification of the flammability of the building materials is the responsibility of the manufacturer of the wooden house, for example), endangerment of irreplaceable goods - cultural assets with a particularly high value and in single-phase final circuits that supply electrical equipment in the areas mentioned or cross these areas. The use of AFDDs is recommended in rooms with sleeping facilities, rooms or places with a fire-spreading structure and final circuits with a high connected load. , In general, the AFDD is also recommended to increase fire protection against electrically ignited fires., LED indicator to identify the cause of the activation. Can be fed in from above or below, cross-wiring e.g. to residual current circuit breakers in the rear terminal area is possible. System pro M compact® accessories can be attached. Rated switching capacity according to IEC/EN 60898-1 Icn=6kA. AFDD+MCB S-ARC1 is 1-pole protected (LS), 2-pole switching.

PropertyValue
Tripping characteristic:B
Size (according to DIN 43880):2
Rated breaking capacity according to IEC 60947-2:10 kA
Rated voltage:230 V
Rated voltage additional device:230 V
Rated current:6 A
Width in modular spacing:2
Installation depth:69 mm
Energy limitation class:4
Frequency:50 Hz
Switching neutral conductor:yes
Number of poles:2
Protection class (IP):IP2X
Type of voltage:AC
Type of control voltage additional device:AC
Overvoltage category:3
Degree of pollution:2
Additional devices fitted at the factory:Fire protection switch
Rated breaking capacity according to EN 61009:10 n/a
Features
HAB
Manufacturer
HAN
GTIN
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated breaking capacity according to IEC 60947-2
Rated voltage
Rated current
Width in pitch units
Installation depth
Energy limitation class
Frequency
Switching neutral conductor
Number of poles
IP protection)
Voltage type
Degree of contamination
Overvoltage category