Description
Features
Reviews
The high-performance circuit breakers in the S800B series protect cables and lines from overload and short circuits. They have a rated short-circuit breaking capacity of 16kA at 230/400V AC. With its thermal tripping mechanism, it offers equally effective protection against overloads, as does its electromechanical tripping mechanism against short circuits. The S800B complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for worldwide use and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800B.
Property | Value |
Tripping characteristic: | B |
Rated current: | 63 A |
Rated voltage: | 400 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 3 |
Number of poles (total): | 3 |
Energy limitation class: | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 82.5 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 10 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 10 kA |
Pollution level: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 3 |
Suitable for flush-mounted installation: | no |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 6 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 0 to 70 mm² |
Connectable conductor cross-section, single-wire: | 0 to 50 mm² |
Features
HAB
S803B-D63 63A 3-pin
Manufacturer
HAN
2CCS813001R0631
GTIN
7612271416089
Connectable conductor cross-section solid
0 to 50 mm²
Connectable conductor cross-section stranded
0 to 70 mm²
Number of protected poles
3
Trigger characteristics
B
Rated insulation voltage Ui
500V
Rated switching capacity Icn according to EN 60898 at 230 V
10kA
Rated switching capacity Icn according to EN 60898 at 400 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
10kA
Rated voltage
400V
Rated impulse withstand voltage Uimp
6kV
Rated current
63 A
Width in pitch units
3
Installation depth
82.5 mm
Energy limitation class
3
Frequency
50 to 60 Hz
Suitable for flush-mounted installation
No
Switching neutral conductor
No
Number of poles (total)
3
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
2
Additional equipment possible
Yes
Overvoltage category
3
No reviews yet — your comment may be first.
All reviews 0