Description
Features
Reviews
The high-performance circuit breakers in the S800B series protect cables and lines against overload and short circuits. They have a rated short-circuit breaking capacity of 16kA at 230/400V AC. With its thermal tripping mechanism, it offers equally effective protection against overload, as does its electromechanical tripping mechanism against short circuits. The S800B complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for worldwide use and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800B.
Property | Value |
Tripping characteristic: | K |
Number of poles (total): | 3 |
Number of protected poles: | 3 |
Rated current: | 80 |
Rated voltage: | 400 |
Rated insulation voltage Ui: | 500 |
Rated impulse withstand voltage Uimp: | 6 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 10 |
Rated switching capacity Icn according to EN 60898 at 400 V: | 10 |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 16 |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 16 |
Type of voltage: | AC |
Frequency: | 50 to 60 |
Energy limitation class: | 3 |
Suitable for flush-mounted installation: | no |
Switching neutral conductor: | no |
Overvoltage category: | 3 |
Pollution degree: | 3 |
Additional equipment possible: | yes |
Width in modular spacing: | 3 |
Installation depth: | 82.5 |
Protection class (IP): | IP20 |
Ambient temperature during operation: | -25 to 60 |
Connectable conductor cross-section, stranded: | 0 to 70 |
Connectable conductor cross-section, single-wire: | 0 to 50 |
Features
HAB
S803B-K80
Manufacturer
HAN
2CCS813001R0627
GTIN
7612271415846
Connectable conductor cross-section solid
0 to 50
Connectable conductor cross-section stranded
0 to 70
Number of protected poles
3
Trigger characteristics
K
Rated insulation voltage Ui
500
Rated switching capacity Icn according to EN 60898 at 230 V
10
Rated switching capacity Icn according to EN 60898 at 400 V
10
Rated switching capacity Icu according to IEC 60947-2 at 230 V
16
Rated switching capacity Icu according to IEC 60947-2 at 400 V
16
Rated voltage
400
Rated impulse withstand voltage Uimp
6
Rated current
80
Width in pitch units
3
Installation depth
82.5
Energy limitation class
3
Frequency
50 to 60
Suitable for flush-mounted installation
No
Switching neutral conductor
No
Voltage type
AC
Ambient temperature during operation
-25 to 60
Degree of contamination
3
Additional equipment possible
Yes
Overvoltage category
3
No reviews yet — your comment may be first.