Description
Features
Reviews
The high-performance circuit breakers in the S800HV series protect cables and lines from overload and short circuits. They have a rated short-circuit breaking capacity of 4kA at 580/1,000V AC. With its thermal tripping mechanism, it offers equally effective protection against overload, as does its electromechanical tripping mechanism against short circuits. The S800HV complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for worldwide use and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800HV.
Property | Value |
Tripping characteristic: | K |
Rated current: | 50 A |
Rated voltage: | 1000 V |
Type of voltage: | AC |
Frequency: | 60 Hz |
Width in modular spacing: | 3 |
Number of poles (total): | 3 |
Energy limitation class: | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 82.5 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 2.5 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 4 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 4 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 2.5 kA |
Pollution level: | 3 |
Switching neutral conductor: | no |
Number of protected poles: | 3 |
Suitable for flush-mounted installation: | no |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 0 to 70 mm² |
Connectable conductor cross-section, single-wire: | 0 to 50 mm² |
Features
HAB
S803HV-K50 50A 3-pole
Manufacturer
HAN
2CCF019042R0001
GTIN
7612271436919
Connectable conductor cross-section solid
0 to 50 mm²
Connectable conductor cross-section stranded
0 to 70 mm²
Number of protected poles
3
Trigger characteristics
K
Rated switching capacity Icn according to EN 60898 at 230 V
2.5kA
Rated switching capacity Icn according to EN 60898 at 400 V
2.5kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
4kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
4kA
Rated voltage
1000V
Rated current
50A
Width in pitch units
3
Installation depth
82.5 mm
Energy limitation class
3
Frequency
60Hz
Suitable for flush-mounted installation
No
Switching neutral conductor
No
Number of poles (total)
3
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
3
Additional equipment possible
Yes
Overvoltage category
3