Description
Features
Reviews
The high-performance circuit breakers in the S800PV-SP series protect cables and lines from overload and short circuits. They have a rated short-circuit breaking capacity of 5 kA at 1,500 V DC for photovoltaic applications. With its thermal release mechanism, it offers equally effective protection against overload, as does its electromechanical release mechanism against short circuits. The S800PV complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for worldwide use and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800PV.
Property | Value |
Tripping characteristic: | B |
Rated current: | 50 A |
Rated voltage: | 1500 V |
Type of voltage: | DC |
Width in modular spacing: | 3 |
Number of poles (total): | 3 |
Energy limitation class: | 3 |
Additional equipment possible: | no |
Overvoltage category: | 3 |
Installation depth: | 111 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 5 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 5 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 5 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 5 kA |
Pollution degree: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 3 |
Suitable for flush-mounted installation: | no |
Rated insulation voltage Ui: | 1500 V |
Rated impulse withstand voltage Uimp: | 8 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 0 to 70 mm² |
Connectable conductor cross-section, solid: | 0 to 50 mm² |
Features
HAB
S803PV-SP50 1.200V DC 50A 3-pin
Manufacturer
HAN
2CCF019617R0001
GTIN
7612271471590
Connectable conductor cross-section solid
0 to 50 mm²
Connectable conductor cross-section stranded
0 to 70 mm²
Number of protected poles
3
Trigger characteristics
B
Rated insulation voltage Ui
1500V
Rated switching capacity Icn according to EN 60898 at 230 V
5kA
Rated switching capacity Icn according to EN 60898 at 400 V
5kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
5kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
5kA
Rated voltage
1500V
Rated impulse withstand voltage Uimp
8kV
Rated current
50A
Width in pitch units
3
Installation depth
111 mm
Energy limitation class
3
Suitable for flush-mounted installation
No
Switching neutral conductor
No
Number of poles (total)
3
IP protection)
IP20
Voltage type
DC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
2
Additional equipment possible
No
Overvoltage category
3