+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

ABB Stotz-Kontakt S804C-D50 high-performance circuit breaker, 2CCS884001R0501

To compare
To favorites
SKU:456181
ABB Stotz-Kontakt S804C-D50 high-performance circuit breaker, 2CCS884001R0501
HAB
Manufacturer
HAN
GTIN
In stock
€416.21
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

The high-performance circuit breakers in the S800C series protect cables and lines against overload and short circuits. They have a rated short-circuit breaking capacity of 25kA at 240/415V AC. In addition, they can be used for voltages up to 400/690V AC and for direct voltages. With its thermal release mechanism, it offers equally effective protection against overloads, as does its electromechanical release mechanism against short circuits. The S800C complies with the IEC/EN 60947-2 standard and can be used for industrial purposes. Numerous approvals make it suitable for worldwide use and the extensive range of accessories makes it even more convenient to use. Thanks to the very fast arc extinguishing, your installation is optimally protected with the S800C.

PropertyValue
Tripping characteristic:D
Rated current:50 A
Rated voltage:440 V
Type of voltage:AC/DC
Frequency:50 to 60 Hz
Width in pitch units:4
Number of poles (total):4
Energy limitation class:3
Additional equipment possible:yes
Overvoltage category:4
Installation depth:82.5 mm
Protection class (IP):IP20
Rated switching capacity Icn according to EN 60898 at 230 V:15 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V:25 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V:25 kA
Rated switching capacity Icn according to EN 60898 at 400 V:15 kA
Pollution degree:3
Switching neutral conductor:no
Number of protected poles:4
Suitable for flush-mounted installation:no
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:8 kV
Ambient temperature during operation:-25 to 60 °C
Connectable conductor cross-section, stranded:0 to 70 mm²
Connectable conductor cross-section single-wire:0 to 50 mm²
Features
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icn according to EN 60898 at 400 V
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
Frequency
Suitable for flush-mounted installation
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category