Description
Features
Reviews
Safety interlock with door monitoring (type 2, DIN EN ISO 14119) for protecting machines that continue to run after the machine has stopped. Locking force FZh = 1500 Newtons, number of door monitoring contacts: 2 break contacts, number of interlock monitoring contacts: 2 break contacts, control voltage of the coil 24 V, with integrated auxiliary release, spring locking principle (closed-circuit principle), cable entry 3 x M20 x 1.5. Actuators must be ordered separately.
Property | Value |
Protection class (IP): | IP67 |
Housing material: | Plastic |
Weight: | 0.48 |
Weight unit: | KG |
Rated operating current Ie at AC-15, 230 V: | 1.5 A |
Rated operating current Ie at DC-13, 230 V: | 0.11 A |
Suitable for safety functions: | yes |
Version of the Switching element: | Slow-action switching element |
Design of the interface for safety-related communication: | without |
Design of the electrical connection: | Cable entry (metric) |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Housing design: | other |
Number of safety-related auxiliary contacts: | 4 |
Design of the interface: | without |
Rated control supply voltage Us magnetic drive at AC 50 Hz: | 24 V |
Rated control supply voltage Us magnetic drive at DC: | 24 V |
Rated operating current Ie at DC-13, 24 V: | 1.5 A |
Width of the sensor: | 42 mm |
Height of the sensor: | 44 mm |
Length of the sensor: | 192 mm |
Ambient temperature during operation: | -25 - 55 °C |
Closing force: | 1500 N |
Number of contacts as normally closed: | 4 |
Housing coating: | other |
With Auxiliary release: | yes |
Type of locking: | Closed-circuit principle |
Features
Rated operating current Ie at DC-13, 230 V
0.11 A
Manufacturer
HAN
6018200007
GTIN
4024337093951
Number of contacts as opener
4
Number of safety-related auxiliary contacts
4
Implementation of the interface
Without
Design of the interface for safety-related communication
Without
Design of the electrical connection
Cable entry (metric)
Rated operating current Ie at AC-15, 230 V
1.5A
Rated operating current Ie at DC-13, 24 V
1.5A
Housing coating
Other
Width of the sensor
42 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
Yes
Housing design
Other
Weight
0,48
Weight unit
kg
Height of the sensor
44 mm
Length of the sensor
192 mm
IP protection)
IP67
Ambient temperature during operation
-25 - 55 °C
Housing material
Plastic
No reviews yet — your comment may be first.