Description
Features
Reviews
Due to normative requirements, the standard rope pull switches can only be used as control devices. Products are available in metal and insulated housings. They are operated manually by pulling on the attached rope. The basic design of the standard rope pull switches is based on that of the position switches.
Property | Value |
Protection class (IP): | IP66/IP67 |
Housing material: | plastic |
Weight: | 0.2 |
Weight unit: | KG |
Switching function: | Slow-action switching element with overlap |
Rated operating current Ie at AC-15, 230 V: | 3 A |
Housing coating: | other |
Design of the interface for safety-related communication: | without |
Design of the electrical Connection: | Cable entry (metric) |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Housing design: | Cuboid |
Positive opening: | yes |
Number of safety-related auxiliary contacts: | 1 |
Design of the actuating element: | other |
Design of the interface: | without |
Rated operating current Ie at DC-13, 24 V: | 1.5 A |
Width of the Sensors: | 42.5 mm |
Height of the sensor: | 41 mm |
Length of the sensor: | 127.5 mm |
Ambient temperature during operation: | -30 - 75 °C |
Number of contacts as normally closed: | 1 |
Number of contacts as normally open: | 1 |
Protection class (NEMA): | 4X |
Features
Manufacturer
HAN
6081000099
GTIN
4024337096969
Number of contacts as normally open
1
Number of contacts as opener
1
Number of safety-related auxiliary contacts
1
Implementation of the interface
Without
Design of the interface for safety-related communication
Without
Design of the actuating element
Other
Design of the electrical connection
Cable entry (metric)
Rated operating current Ie at AC-15, 230 V
3 A
Rated operating current Ie at DC-13, 24 V
1.5A
Housing coating
Other
Width of the sensor
42.5 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Housing design
Cuboid
Weight
0,2
Weight unit
kg
Height of the sensor
41 mm
Length of the sensor
127.5 mm
Switching function
Slow-action contact with overlap
IP protection)
IP66/IP67
Protection class (NEMA)
4X
Ambient temperature during operation
-30 - 75 °C
Housing material
Plastic
Forced opening
Yes
No reviews yet — your comment may be first.
All reviews 0