Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 2 are two-pole residual current circuit breakers for single-phase networks. In the standard version, the compact devices are two division units wide. They are available with many different residual current types and versions with rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type B switches are universal current sensitive. They protect against pulse and alternating residual currents, residual currents with mixed frequencies and smooth direct residual currents at frequencies up to 150 kHz. They are resistant to increased surge currents and storms. The universal current sensitive residual current circuit breakers of the NK series offer the classic fire protection of 300 mA at frequencies from 0 to 150 kHz. They are optimized for fire-prone premises. Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: - meets the requirements of the building regulations 0664-10, 0664-40, 0664-400, ÖVE/ÖNORM E 8601 - universal current sensitive for fault currents with frequencies and mixed frequencies from 0Hz (smooth direct current) to 150 kHz, - electromagnetic compatibility in accordance with VDE0664-30 and VDE0839-6-2 (interference immunity for industrial applications) - mains voltage-independent tripping for type A fault currents, - voltage-dependent detection of smooth direct fault current and alternating fault currents with frequencies 50/60Hz, - full functionality with mains voltages from at least 50VAC on any two active conductors - small size for all rated currents, - high short-circuit strength, - double-sided double-deck terminals for large conductor cross-sections and rail connections, - switch position indicator, - viewing window for labels, - multifunctional switch toggle with three positions: 'on', 'off', 'triggered', - also available in the 'HD' version - neutral conductor position as desired Mounting type: - quick fastening on mounting rail - installation position as desired - feed preferably from above Areas of application: - commercial and industrial installations with TN-S, TT and TN-CS systems in which power electronics equipment without galvanic mains isolation is used, such as frequency converters, switched-mode power supplies, high-frequency converters, photovoltaic and UPS systems with transformerless inverters., - operating locations at risk of fire Notes: - suitable for use in 50 Hz alternating current networks, - RCCB for other frequencies on request, - Not intended for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters.
Property | Value |
Rated voltage: | 230 V |
Rated current: | 40 A |
Rated residual current: | 0.3 mA |
Mounting type: | DIN rail |
Protection class (IP): | IP20 |
Frequency: | 50 Hz |
Number of poles: | 2 |
Width in pitch units: | 2 |
Selective type: | no |
Residual current type: | B |
Additional equipment possible: | yes |
Installation depth: | 69 mm |
Short-circuit strength (Icw): | 10 kA |
Surge current strength: | 3 kA |
Short-time delayed type: | yes |
Rated insulation voltage Ui: | 400 V |
Rated impulse withstand voltage Uimp: | 4 kV |
With locking device: | yes |
Ambient temperature during Operating: | -25 to 40 °C |
Pollution level: | 2 |
Connectable conductor cross-section, stranded: | 1.5 to 50 mm² |
Connectable conductor cross-section, single-wire: | 1.5 to 50 mm² |