+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Doepke 09136905 DFS4 040-4/0.30-AS 40/0.3A 4-pole residual current circuit breaker

Brand:Doepke
To compare
To favorites
SKU:324102
Doepke 09136905 DFS4 040-4/0.30-AS 40/0.3A 4-pole residual current circuit breaker
HAB
Manufacturer
HAN
GTIN
In stock
€112.21
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breakers (RCCBs) switch off the power supply when dangerously high fault currents occur. In this way they protect people, animals and systems. DFS 4 are two- or four-pole residual current circuit breakers for single- or three-phase networks. In the standard version, the compact devices are four module widths. They are available with many different residual current types and versions for rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type A switches are sensitive to pulse and alternating current. This function is independent of the mains voltage. Selective residual current circuit breakers are used in systems with staggered distributions. In the event of a fault, only the switch in whose system section the fault current is present trips. The selective RCCBs offer fire and fault protection (in the event of indirect contact), but not additional protection (direct contact, personal protection). Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Features: - response delay for selective execution, - high immunity to surge fault currents and mains voltage-driven follow-on current pulses - tripping independent of mains and auxiliary voltage, - sensitive to alternating and pulsating direct fault currents (type A) - small size for all rated currents, - high short-circuit strength, - double-sided double-deck terminals for large conductor cross-sections and busbar connections, - switch position indicator, - viewing window for labels, - multifunctional switch toggle with three positions: 'on', 'off', 'tripped', - also available in the 'HD' version - neutral conductor position on the left, also available as N on the right at no extra charge. Mounting type: - Quick fastening on mounting rail - Any installation position - Any feed direction Applications: - Main distribution boards in extensive power supplies with TN-S, TT and TN-CS systems, e.g. for campsites, marinas, allotments, showgrounds. Selective residual current circuit breakers protect the cables from the main distribution board to the sub-distribution boards. - Not suitable for use in TN-C networks and for protecting systems in which electronic equipment can cause smooth DC residual currents or residual currents with frequencies other than 50 Hz. Comprehensive protection is not provided here. For such applications, we recommend our universal current-sensitive residual current circuit breakers (type B or B+). Notes: - To ensure the selectivity of the RCCB, the rated residual current of the selective RCCB must be at least one level higher than that of the downstream instantaneous switch.

PropertyValue
Rated voltage:400 V
Rated current:40 A
Rated residual current:0.3 mA
Mounting type:DIN rail
Protection class (IP):IP20
Frequency:50 Hz
Number of poles:4
Width in pitch units:4
Selective type:yes
Residual current type:A
Additional devices possible:yes
Installation depth:69 mm
Short-circuit strength (Icw):10 kA
Surge current strength:5 kA
Short-time delayed type:no
Rated impulse withstand voltage Uimp:4 kV
With locking device:yes
Ambient temperature during operation:-25 to 40 °C
Pollution level:2
Connectable conductor cross-section, stranded:1.5 to 50 mm²
Connectable conductor cross-section, single-wire:1.5 to 50 mm²
Features
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Rated residual current
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Residual current type
Frequency
Short circuit strength (Icw)
Short-time delayed type
With locking device
Mounting type
Number of poles
IP protection)
Selective type
Surge current strength
Ambient temperature during operation
Degree of contamination
Additional equipment possible
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Doepke 09932115 DRCBO 3 B20/0.3/1N-A /RCBO FI/LS combination
Doepke 09932115 DRCBO 3 B20/0.3/1N-A /RCBO FI/LS combination
113.16
In stock
Doepke 09916174 DLS6I B20A 4-pole 10KA circuit breaker
Doepke 09916174 DLS6I B20A 4-pole 10KA circuit breaker
111.22
In stock
Doepke 09916142 DLS6I B13A 3-pole+N 10KA circuit breaker
Doepke 09916142 DLS6I B13A 3-pole+N 10KA circuit breaker
111
In stock
Doepke 09916418 DLS6I D50A 1-pole+N 10KA circuit breaker
Doepke 09916418 DLS6I D50A 1-pole+N 10KA circuit breaker
110.58
In stock
Doepke 9912084 DLS 6hdc B20-2 circuit breaker
Doepke 9912084 DLS 6hdc B20-2 circuit breaker
110.10
In stock
Doepke 09500110 EDS 16 with light sensor LF1 twilight switch
Doepke 09500110 EDS 16 with light sensor LF1 twilight switch
109.91
In stock
Doepke 09945104 DRCBO 4 B16/0.03/3N-A FI/LS combination
Doepke 09945104 DRCBO 4 B16/0.03/3N-A FI/LS combination
115.10
In stock