Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. They thus protect people, animals and systems. DFS 2 are two-pole residual current circuit breakers for single-phase networks. In the standard version, the compact devices are two division units wide. They are available with many different residual current types and versions with rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type B switches are universally sensitive. They protect against pulse and alternating residual currents, residual currents with mixed frequencies and smooth direct residual currents at frequencies up to 150 kHz. They are resistant to increased surge currents and storms. SK series residual current circuit breakers stand for residual current protection and high system availability. They are characterized by a lower response sensitivity at higher frequencies. The SK characteristic curve is optimized for systems in which no fire protection is required. Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: - high immunity to operational leakage and fault currents at frequencies from 1 kHz, - meets the requirements of the building regulations 0664-10, 0664-40, ÖVE/ÖNORM E 8601 - universal current sensitive for fault currents with frequencies and mixed frequencies from 0Hz (smooth direct current) to 150 kHz, - electromagnetic compatibility in accordance with VDE0664-30 and VDE0839-6-2 (interference immunity for industrial applications) - mains voltage-independent tripping for type A fault currents, - voltage-dependent detection of smooth direct fault current and alternating fault currents with frequencies 50/60Hz, - full functionality with mains voltages from at least 50VAC on any two active conductors - small size for all rated currents, - high short-circuit strength, - double-sided double-deck terminals for large conductor cross-sections and rail connection, - switch position indicator, - viewing window for Labeling labels, - multi-function switch toggle with three positions: 'on', 'off', 'triggered', - also available in the 'HD' version - neutral conductor can be positioned anywhere Mounting type: - quick attachment to mounting rail - installation position can be chosen anywhere - feed-in preferably from above Areas of application: - commercial and industrial installations with TN-S, TT and TN-CS systems in which power electronics equipment is used without galvanic mains isolation, such as frequency converters, switched-mode power supplies, high-frequency power converters, photovoltaic and UPS systems with transformerless inverters., - also ideal for heat pumps or photovoltaic systems in, for example, new buildings. Notes: - suitable for use in 50 Hz alternating current networks, - RCCB for other frequencies on request, - not intended for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters.
Property | Value |
Rated voltage: | 230 V |
Rated current: | 63 A |
Rated residual current: | 0.3 mA |
Mounting type: | DIN rail |
Protection class (IP): | IP20 |
Frequency: | 50 Hz |
Number of poles: | 2 |
Width in pitch units: | 2 |
Selective type: | no |
Residual current type: | B |
Additional equipment possible: | yes |
Installation depth: | 69 mm |
Short-circuit strength (Icw): | 10 kA |
Surge current strength: | 3 kA |
Short-time delayed type: | yes |
Rated insulation voltage Ui: | 400 V |
Rated impulse withstand voltage Uimp: | 4 kV |
With locking device: | yes |
Ambient temperature during Operating: | -25 to 40 °C |
Pollution level: | 2 |
Connectable conductor cross-section, stranded: | 1.5 to 50 mm² |
Connectable conductor cross-section, single-wire: | 1.5 to 50 mm² |