Residual current circuit breakers (RCCB) switch off the power supply when dangerously high residual currents occur. In this way, they protect people, animals and systems. DFS 4 are two- or four-pole residual current circuit breakers for single- or three-phase networks. In the standard version, the compact devices are four division units wide. They are available with many different residual current types and versions with rated currents of up to 125 A. The large double-deck terminals can also accommodate large conductor cross-sections. The tripped position of the multi-function switch toggle makes troubleshooting easier. The free label software helps with labeling. Type A switches are sensitive to pulse and alternating current. This function is independent of the mains voltage. Residual current circuit breakers in KV version (KV for short-time delayed) are considerably less sensitive to short-term pulse-shaped surge and residual currents. In this way, they increase system availability. The additional protection (personal protection) is retained. The short-time delayed switches can therefore be used without any problem instead of a standard switch. Standard devices are designed for monitoring circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Features: - high immunity to surge fault currents and mains voltage-driven follow-on current pulses - tripping independent of mains and auxiliary voltage, - sensitive to alternating and pulsating direct fault currents (type A) - small size for all rated currents, - high short-circuit strength, - double-sided double-deck terminals for large conductor cross-sections and busbar connections, - switch position indicator, - viewing window for labels, - multifunctional switch toggle with three positions: 'on', 'off', 'tripped', - also available in the 'HD' version - neutral conductor position on the left, also available as N on the right at no extra charge. Mounting type: - Quick attachment to mounting rail - Any installation position - Any feed direction Application areas: - Power supplies for residential and commercial buildings as well as industrial plants with TN-S, TT and TN-CS networks in which conventional RCCBs trigger undesirably as a result of transient leakage currents, such as systems with long cable lengths behind the RCCB, lighting systems with many fluorescent lamps (> 20), computer systems and solariums. - Not suitable for use in TN-C networks or for protecting systems in which electronic equipment can cause smooth DC fault currents or fault currents with frequencies other than 50 Hz. Comprehensive protection is not provided here. For such applications we recommend our universal current sensitive residual current circuit breakers (type B or B+).
Property | Value |
Rated voltage: | 400 V |
Rated current: | 63 A |
Rated residual current: | 0.3 mA |
Mounting type: | DIN rail |
Protection class (IP): | IP20 |
Frequency: | 50 Hz |
Number of poles: | 4 |
Width in pitch units: | 4 |
Selective type: | no |
Residual current type: | A |
Additional equipment possible: | yes |
Installation depth: | 69 mm |
Short-circuit strength (Icw): | 10 kA |
Surge current strength: | 3 kA |
Short-time delayed type: | yes |
Rated insulation voltage Ui: | 400 V |
Rated impulse withstand voltage Uimp: | 4 kV |
With locking device: | yes |
Ambient temperature during Operating: | -25 to 40 °C |
Pollution level: | 2 |
Connectable conductor cross-section, stranded: | 1.5 to 50 mm² |
Connectable conductor cross-section, single-wire: | 1.5 to 50 mm² |