Doepke 09209784 DFL8 200-4/XB SK 4-pole 200/X residual current circuit breaker

Brand:Doepke
To compare
To favorites
SKU:323883
Doepke 09209784 DFL8 200-4/XB SK 4-pole 200/X residual current circuit breaker
Shutdown characteristics
HAB
Manufacturer
HAN
In stock
€3,507.16
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breakers with residual current protection (CBR) switch high currents, protect equipment, cables and lines from overcurrent and people from electric shock. DFL 8 are compact devices with an integrated auxiliary switch and connection terminals for large cable cross-sections. Type B switches are sensitive to all currents. They protect against pulse and alternating residual currents, residual currents with mixed frequencies and smooth direct residual currents at frequencies up to 150 kHz. They are resistant to increased surge currents and storms. Switches with the SK characteristic curve stand for residual current protection and high system availability. They are characterized by a lower response sensitivity at higher frequencies. Undesired tripping due to leakage currents is thus largely avoided. With switches of this variant, the fault response current can be individually set in stages to suit the respective application (0.30 A, 0.50 A, 1.00 A). The limit non-response time can also be set in stages accordingly. This makes it possible to implement a selective residual current protection circuit in systems with staggered distributions. Standard devices are designed to monitor circuits with a rated voltage of 230 V/400 V and a rated frequency of 50 Hz. Properties: - adjustable rated residual current - rated currents from 100A to 250A, - rated voltage 230 V, 400 V AC, - four-pole, - residual current detection for smooth direct current as well as alternating and pulsating direct currents, - high tolerance to fluctuations in the auxiliary voltage when detecting residual currents type B, - mains and auxiliary voltage independent tripping for residual currents of type A and in the event of overcurrent, - high short-circuit switching capacity, - connection terminals up to 185mm - thresholds for instantaneous and delayed overcurrent tripping adjustable - high surge current strength, i.e. low tendency to false tripping due to transient residual currents - auxiliary switch integrated Mounting type: - attachment to mounting plate - installation position as required - feed from below Application areas: - staggered power supply systems with TN-S, TT and TN-CS networks with high short-circuit power in commercial buildings and industry - In IT networks, the residual current tripping of the CBR can be provided for shutdown in the event of a second earth fault. - Due to its universal current sensitive residual current tripping, this universal current sensitive CBR is particularly suitable for protecting systems with electronic equipment that is not galvanically isolated from the mains on the input side. - It cannot be used for residual current protection in TN-C networks

PropertyValue
Tripping characteristics:other
Rated current:200 A
Rated residual current:0.3 A
Rated voltage:400 V
Frequency:50 Hz
Number of poles (total):4
Residual current type:B
Installation depth:149 mm
Rated breaking capacity according to IEC 60947-2:85 kA
Surge current strength:5 kA
Protection class (IP):IP20
Overvoltage category:3
Pollution level:3
Switching neutral conductor:yes
Number of protected poles:3
Voltage type:AC
False tripping protection:no
Rated impulse withstand voltage Uimp:4 kV
Shutdown characteristic:short-time delayed
With locking device:yes
Ambient temperature during operation:-25 to 70 °C
Connectable conductor cross-section, single-wire:4 to 16 mm²
Connectable conductor cross-section, stranded:25 to 185 mm²
Features
Shutdown characteristics
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Installation depth
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category