The purpose of circuit breakers is to automatically switch off circuits to protect cables and connected devices. After switching off, they can be switched on again manually without, for example, having to replace fuse inserts. Each of our circuit breakers is equipped with a trip-free mechanism that ensures safe switching off, even if, for example, the switch knob is mechanically blocked. Circuit breakers in the DLS 6 series protect cables, lines and installation devices against overload and short circuits in accordance with DIN0100. The series includes a large selection of different types, from switches for residential and commercial buildings to switches for industrial use. Thanks to their compact design, circuit breakers in the DLS 6 series offer maximum space for convenient wiring. The large clamping range and the option of using commercially available wiring rails ensure easy installation. In addition, a large number of additional devices such as shunt releases and auxiliary and fault indicators can be connected. The screwless version DLS 6hsl for tradesmen is suitable for distribution and final circuits with its rated switching capacity of 6 kA. It is particularly easy to process thanks to the upper, screwless plug-in terminals. Switches with tripping characteristic B ensure standard protection for light and socket circuits. Properties: Rated switching capacity 6 kA, upper screwless plug-in terminal for convenient and quick installation, lower clamping yoke terminals with a wide clamping cross-section range for rails, special quick fastening for removing several circuit breakers from the lower or upper rail assembly, large, hinged labeling window for a secure hold and protection of the label, use of commercially available wiring rails, ON/OFF switch position indicator on the switch knob, accessories can be retrofitted on the right, free labeling software, type of installation: quick fastening on mounting rail, installation position as desired, areas of application: suitable for use in power supplies for residential buildings and purpose-built or commercial buildings.
Property | Value |
Tripping characteristic: | B |
Rated current: | 16 A |
Rated voltage: | 400 V |
Type of voltage: | AC/DC |
Frequency: | 16.67 to 60 Hz |
Width in pitch units: | 1 |
Number of poles (total): | 1 |
Energy limitation class: | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 68.7 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 6 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 6 kA |
Pollution degree: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 1 |
Rated insulation voltage Ui: | 2 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Ambient temperature during operation: | -25 to 55 °C |
Connectable conductor cross-section, stranded: | 1.5 to 4 mm² |
Connectable conductor cross-section, solid: | 1 to 4 mm² |