Doepke 09932144 DRCBO 3 B16/0.01/1N-A FI/LS combination

Brand:Doepke
To compare
To favorites
SKU:323805
Doepke 09932144 DRCBO 3 B16/0.01/1N-A FI/LS combination
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
HAB
Manufacturer
In stock
€95.96
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

FI/LS combinations (RCBO) are circuit breakers with residual current releases for protecting systems in the event of short circuits and overloads in accordance with the requirements of 0100 Part 430 and for protecting people, livestock and property in the event of earth fault currents in accordance with 0100 Part 410. The overcurrent release is triggered by a slow-acting, heat-sensitive bimetal release for currents in the overload range and by an electromagnetic quick-release release for short-circuit currents. The high-quality FI/LS combinations of the DRCBO 3 series are independent of the mains voltage and are characterized by a high rated switching capacity of 10 kA. The green-red contact position indicator and the residual current release indicator provide a quick overview of the operating status of the devices. Both the clamping aid rear plug protection and the tristable locking slide make installation and removal easier. RCBOs with residual current characteristic A are independent of the mains voltage and enable the detection of sinusoidal alternating and pulsating direct residual currents. RCBOs with B characteristics ensure standard protection for lighting and socket circuits. Since their short-circuit tripping is three to five times the value of the rated current, they should not be used to protect load circuits with high inrush currents. Standard devices are designed to monitor circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz, and in some series also 60 Hz. Features: - mains voltage independent tripping - small size for all rated currents - high short-circuit strength - green-red contact position indicator - residual current trip indicator - tension clamp terminals with rear protection and wide clamp cross-section range for rail and line wiring on both connection sides - use of commercially available wiring rails possible - neutral conductor on the right

PropertyValue
Tripping characteristic:B
Rated current:16 A
Rated residual current:0.01 A
Rated voltage:230 V
Frequency:50 Hz
Number of poles (total):2
Width in pitch units:2
Residual current type:A
Installation depth:68 mm
Surge current strength:0.25 kA
Protection class (IP):IP20
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:1
Voltage type:AC
False tripping protection:no
Rated insulation voltage Ui:440 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1:10 kA
Shutdown characteristics:instantaneous
With locking device:yes
Ambient temperature during operation:-25 to 40 °C
Connectable conductor cross-section, single-wire:1 to 25 mm²
Connectable conductor cross-section, stranded:1 up to 16 mm²
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Doepke 09932428 DRCBO 3 C40/0.03/1N-A KV FI/LS combination
Doepke 09932428 DRCBO 3 C40/0.03/1N-A KV FI/LS combination
95.78
In stock
Doepke 09700108 FSE 1 mains disconnector
Doepke 09700108 FSE 1 mains disconnector
96.76
In stock
Doepke 09916620 DLS6I K8A 2-pole 10KA circuit breaker
Doepke 09916620 DLS6I K8A 2-pole 10KA circuit breaker
94.96
In stock
Doepke Champ 2 GS-L/F 05 m float switch, 09921056
Doepke Champ 2 GS-L/F 05 m float switch, 09921056
97.01
In stock
Doepke 09915031 ELS C6A 1-pole+N 1TE circuit breaker
Doepke 09915031 ELS C6A 1-pole+N 1TE circuit breaker
94.67
In stock
Doepke 09916143 DLS6I B16A 3-pole+N 10KA circuit breaker
Doepke 09916143 DLS6I B16A 3-pole+N 10KA circuit breaker
94.51
In stock
Doepke 09916088 DLS6I B50A 2-pole 10KA circuit breaker
Doepke 09916088 DLS6I B50A 2-pole 10KA circuit breaker
97.82
In stock