RCBOs combine residual current and circuit breakers in one device (FI/LS combination). They protect people from residual currents and systems from short circuits and overloads. DRCBO 4 have a rated switching capacity of 6 kA. In addition to the tripped indicator, they also have a labeling window. Type B switches are sensitive to all currents at frequencies from 0 Hz (smooth DC residual currents) to 150 kHz. They are resistant to increased surge currents and storms. Switches with the NK characteristic curve offer classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimized for fire-prone premises. Switches with the B tripping characteristic are the standard protection for light and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz. Properties: universally sensitive for fault currents with frequencies from 0 Hz (smooth direct current) to 150 kHz, tripping independent of the mains voltage for fault currents of type A, small size for all rated currents, switch position indicator, separate display of the reason for tripping, clamping yoke terminals with a wide clamping cross-section range on both connection sides, neutral conductor on the right, labeling window, mounting type: quick fastening on mounting rail, installation position as desired, feed preferably from above, areas of application: commercial and industrial installations with TT, TN-S and TN-CS systems in which power electronics equipment is used without galvanic mains isolation, such as frequency converters, switched-mode power supplies, high-frequency power converters, photovoltaic or UPS systems with transformerless inverters, RCBO of type B+ and type B with NK characteristics are to be used there. where fire protection is required, Notes: suitable for use in 50 Hz alternating current networks, RCBOs are also available for other frequencies on request, not intended for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters.
Property | Value |
Tripping characteristic: | B |
Rated current: | 32 A |
Rated residual current: | 0.3 A |
Rated voltage: | 230 V |
Frequency: | 50 Hz |
Number of poles (total): | 2 |
Width in pitch units: | 2.5 |
Residual current type: | B |
Installation depth: | 67 mm |
Surge current strength: | 3 kA |
Protection class (IP): | IP20 |
Energy limitation class: | 3 |
Overvoltage category: | 3 |
Pollution degree: | 2 |
Switching neutral conductor: | yes |
Number of protected poles: | 1 |
Voltage type: | AC |
False tripping protection: | no |
Rated insulation voltage Ui: | 440 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Rated breaking capacity according to EN 61009: | 6 kA |
Rated short-circuit breaking capacity Icn according to EN 61009-1: | 6 kA |
Shutdown characteristics: | short-time delayed |
With locking device: | no |
Ambient temperature during operation: | -25 to 40 °C |
Connectable conductor cross-section, single-wire: | 1 to 35 mm² |
Connectable conductor cross-section stranded: | 1 to 25 mm² |