RCBOs combine residual current and circuit breakers in one device (FI/LS combination). They protect people from residual currents and systems from short circuits and overloads. This series has a rated switching capacity of 6 kA. FIB/FIC are available as pulse and alternating current sensitive type A three-pole +N and as universal current sensitive type B single-pole +N or three-pole +N. Type A switches are pulse and alternating current sensitive. This function is independent of the mains voltage. Switches with tripping characteristic B are the standard protection for light and socket circuits. Standard switches are designed for circuits with a rated voltage of 230V or 400V and a rated frequency of 50Hz. Properties: - tripping independent of mains voltage, - small size for all rated currents, - high short-circuit strength, - switch position indicator, - separate display of the reason for the fault, - clamping yoke terminals with a wide clamping cross-section range on both connection sides, - neutral conductor on the right, - high electromagnetic compatibility (interference immunity for industrial applications) Mounting type: - quick attachment to mounting rail - installation position as desired Areas of application: - protection of circuits in residential and commercial buildings as well as industrial plants with TN-S and TN-CS networks. In IT networks, FI/LS switches can be provided to switch off in the event of a second earth fault. - Use in systems with TN-C networks and to protect circuits in which power electronics equipment can cause smooth DC fault currents or fault currents with frequencies other than 50/60 Hz is excluded.
| Property | Value |
| Tripping characteristic: | B |
| Rated current: | 40 A |
| Rated residual current: | 0.03 A |
| Rated voltage: | 400 V |
| Frequency: | 50/60 Hz |
| Number of poles (total): | 4 |
| Width in pitch units: | 5 |
| Residual current type: | A |
| Installation depth: | 68 mm |
| Surge current resistance: | 0.25 kA |
| Protection class (IP): | IP20 |
| Energy limitation class: | 3 |
| Overvoltage category: | 3 |
| Pollution degree: | 2 |
| Switching neutral conductor: | no |
| Number of protected poles: | 3 |
| Suitable for flush-mounted installation: | no |
| Voltage type: | AC |
| False tripping protection: | no |
| Rated insulation voltage Ui: | 440 V |
| Rated impulse withstand voltage Uimp: | 4 kV |
| Rated breaking capacity according to EN 61009: | 6 kA |
| Rated short-circuit breaking capacity Icn according to EN 61009-1: | 6 kA |
| Shutdown characteristic: | instantaneous |
| With locking device: | no |
| Ambient temperature during operation: | -25 to 40 °C |
| Connectable conductor cross-section, solid: | 1 to 35 mm² |
| Connectable conductor cross-section stranded: | 1 to 25 mm² |