+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Doepke 09962102 DAFDD 1 C10/0.03/2-A fire protection switch

Brand:Doepke
To compare
To favorites
SKU:323673
Doepke 09962102 DAFDD 1 C10/0.03/2-A fire protection switch
HAB
Manufacturer
HAN
GTIN
In stock
€167.60
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Arc fault protection devices (fire protection switches, AFDD) are devices for protection against serial and parallel arc faults in accordance with the requirements of DIN0100-420. They are colloquially referred to as 'fire protection switches'. They are mandatory for permanently installed final circuits up to 16 A in, for example, fire-prone workplaces or public facilities. They are recommended for bedrooms and final circuits with high connected loads, among other things. The devices detect high-frequency arc faults, such as those that can occur due to defects in the wiring. The early detection and subsequent shutdown of the final circuit if necessary prevents thermal influences from the arc fault. The risk of fire due to faulty electrical installation is significantly reduced. The respective reason for the trip is displayed via a color code of the LED on the front of the device. The DAFDD 1 are compact combination devices with a triple function: arc fault detection, line protection and residual current tripping. They meet the requirements of 0100 Part 430 for the protection of systems in the event of short circuits and overloads, and for the protection of people, livestock and property in the event of earth fault currents in accordance with 0100 Part 410. The RCBO part (FI/LS functions) is independent of the mains voltage. With the residual current type A, sinusoidal alternating and pulsating direct residual currents can be detected. The contact position indicators and the residual current tripping indicator provide a quick overview of the operating status of the device. The devices up to 25 A are also characterized by a high rated switching capacity of 10 kA, the 32 A and 40 A devices of 6 kA. The line protection of the C characteristic is primarily suitable for power circuits with high inrush or peak currents. Devices in standard design are for the monitoring of

PropertyValue
Rated current:10 A
Number of poles:2
Tripping characteristic:C
Rated residual current:0.03 A
Rated switching current additional device:10 A
Rated voltage:240 V
Rated voltage additional device:240 V
Frequency:50 Hz
Width in pitch units:3
Installation depth:70 mm
Energy limitation class:3
Residual current type:A
Switching neutral conductor:no
Protection class (IP):IP20
Control voltage type additional device:AC
Overvoltage category:3
Pollution level:2
Additional devices fitted at the factory:Fire protection switch
Rated breaking capacity according to EN 61009:10 n/a
Features
HAB
Manufacturer
HAN
GTIN
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated residual current
Rated voltage
Rated current
Width in pitch units
Installation depth
Energy limitation class
Residual current type
Frequency
Suitable for outdoor use
Switching neutral conductor
Number of poles
IP protection)
Degree of contamination
Overvoltage category