Description
Features
Reviews

The purpose of circuit breakers is to automatically switch off circuits to protect cables and connected devices. After switching off, they can be switched on again manually without, for example, having to replace fuse inserts. Each of our circuit breakers is equipped with a trip-free mechanism that ensures safe switching off, even if, for example, the switch knob is mechanically blocked. Circuit breakers in the DLS 6 series protect cables, lines and installation devices against overload and short circuits in accordance with DIN0100. The series includes a large selection of different types, from switches for residential and commercial buildings to switches for industrial use. Thanks to their compact design, circuit breakers in the DLS 6 series offer maximum space for convenient wiring. The large clamping range and the option of using commercially available wiring rails ensure easy installation. In addition, a large number of additional devices such as shunt releases and auxiliary and fault indicators can be connected. The DLS 6hdc version for direct current networks is suitable for distribution and final circuits with its rated switching capacity of 6 kA. Switches with tripping characteristic B ensure standard protection for lighting and socket circuits. Properties: for use in direct current networks, rated switching capacity 6 kA, clamping yoke terminals with a wide clamping cross-section range for rail and cable wiring on both connection sides, special quick fastening for removing several circuit breakers from the lower or upper rail assembly, large, hinged labeling window for secure hold and protection of the label, use of commercially available wiring rails, ON/OFF switch position indicator on the switch knob, accessories can be retrofitted on the right, free labeling software, mounting type: quick fastening on mounting rail, installation position as desired, areas of application: suitable for use in direct current supplies for residential buildings and purpose-built or commercial buildings. Notes: Influence of the ambient temperature on the thermal tripping: Reduction of the current values at higher ambient temperatures and increase at lower temperatures by approx. 5% per 10 degrees C temperature difference. For 2-pole devices, the series connection of the poles must be observed.

PropertyValue
Tripping characteristic:B
Rated current:10 A
Rated voltage:250 V
Type of voltage:DC
Width in modular spacing:2
Number of poles (total):2
Additional equipment possible:yes
Installation depth:68 mm
Protection class (IP):IP20
Rated switching capacity Icn according to EN 60898 at 230 V:6 kA
Rated switching capacity Icn according to EN 60898 at 400 V:6 kA
Pollution degree:2
Switching neutral conductor:no
Number of protected poles:2
Rated insulation voltage Ui:2 V
Rated impulse withstand voltage Uimp:4 kV
Ambient temperature during operation:-25 to 55 °C
Connectable conductor cross-section stranded:1.5 to 25 mm²
Connectable conductor cross-section single-wire:0.5 to 25 mm²
Features
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icn according to EN 60898 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Ambient temperature during operation
Degree of contamination
Additional equipment possible