Draka patch cable for indoor use UC300 S26 C5E F/UTPP 4P LSHF Cat.5 copper data cable for structured cabling with a bandwidth of 300 MHz. The cable is simply shielded with twisted pairs and a foil shield. The 4-pair simplex patch cable with 8 AWG26 copper wires is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted. It exceeds the requirements of EN 50173-1, EN 50288-2-2, ISO/IEC 11801 and IEC 61156-6. The jacket is made of halogen-free, flame-retardant material in accordance with IEC 60332-1, IEC 60754-2, IEC 61034 and Eurofire class Eca. With a coupling attenuation of 55 dB, the shielding meets separation class C according to EN50174. The cable is future-proof for all applications according to class C and D and suitable for operating PoE and PoE+ over a channel length of max. 60 m. It is suitable for the following transmissions: connection cable for telephony, Ethernet, Fast Ethernet and Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T or up to 1,000 Mbit/s.
Property | Value |
Number of cores: | 8 |
Outer diameter approx.: | 5.6 mm |
AWG cross-section: | 26 |
Conductor class: | Cl.2 = stranded |
Stranding element: | pairs |
Core marking: | Color |
Shield over stranding element: | without |
Category: | 5 |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | yes |
Sheath color: | yellow |
Conductor nominal cross-section: | 0.14 mm² |
Conductor diameter: | 0.42 mm |
Stranding: | Layers |
Material of the core insulation: | Polyolefins |
Number of stranding elements: | 4 |
Shield over stranding: | Foil |
Conductor surface: | bare |
Protective jacket: | no |
Reinforcement: | no |
Jacket material: | Polyolefins |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Functional integrity: | no |
Permissible external cable temperature during assembly/handling: | 0 to 50 °C |
Permissible External cable temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 67 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Eca |
Min. permissible bending radius, flexible use with forced guidance: | 56 mm |
Min. permissible bending radius, flexible use/free movement: | 33 mm |
Min. permissible bending radius, stationary use/fixed installation: | 33 mm |
Laying in the ground: | no |
UV-resistant: | no |