Draka installation cable for indoor use UC HOME SS22 Cat.7A S/FTP 4P LSHF DcaCat.7A copper data cable for structured cabling with a bandwidth of 1000 MHz.With foil pair shielding and high-quality braided cover, the cable is double shielded.The 4-pair simplex installation cable with 8 copper wires AWG22 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted.The product exceeds the requirements of EN50173-1 EN50288-9-1, ISO/IEC11801 IEC61156-5, IEC61156-7 and IEEE802.3af/at/bt.The jacket is made of halogen-free, flame-retardant material in accordance with IEC60332-1 IEC60754-2 IEC61034 EN50399 and Eurobrand class Dca s1 d1 a1. The shielding meets the separation class D according to EN50174 with a coupling attenuation of 85 dB. The cable is future-proof for all applications according to class C, D, E, EA, F and FA and suitable for the operation of PoE and PoE+ over a channel length of up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet and Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T, 10GBase-T and for 25GBase-T over 30m
Property | Value |
Weight: | 0.07 |
Weight unit: | KG |
Conductor nominal cross-section: | 0.32 mm² |
Material of core insulation: | Polyolefins |
Core marking: | Color |
Stranding element: | Pairs |
Sheath color: | white |
Category: | 7A (IEC) |
Conductor diameter: | 0.64 mm |
Shield over stranding element: | Foil |
Shield over stranding: | Braid |
Sheath material: | Polyolefines |
Conductor class: | Class 1 = single wire |
Permissible external cable temperature during assembly/handling: | 10 - 40 °C |
Permissible Cable external temperature after installation without vibration: | -20 - 60 °C |
Number of stranding elements: | 4 |
Number of cores: | 8 |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Stranding: | layers |
Outer diameter approx.: | 7.6 mm |
NVP value: | 79 % |
Conductor surface: | bare |
Fire behavior class according to EN 13501-6: | Dca |
Smoke development class according to EN 13501-6: | s1 |
Drip behaviour class according to EN 13501-6: | d1 |
Acid development class according to EN 13501-6: | a1 |
Min. permissible bending radius, flexible use with forced guidance: | 60 mm |
Min. permissible bending radius, flexible use/free movement: | 30 mm |
Min. permissible bending radius, stationary use/fixed installation: | 30 mm |
Specification of core insulation: | Polyethylene (PE) |
Specification of sheath material: | other |
Copper number: | 4.04 /100m |
Copper base: | 150.00 EUR/100kg |