Draka installation cable for indoor use UC HOME SS26 Cat.7 S/FTP 2X4P LSHF DcaCat.7 copper data cable for structured cabling with a bandwidth of 600 MHz.With foil pair shielding and high-quality braided cover, the cable is double shielded.The 2x4-pair duplex installation cable with 2x8 copper strands AWG26 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted.The product exceeds the requirements of EN50173-1, EN50288-4-2, ISO/IEC11801, IEC61156-6 and IEEE802.3 af/at/bt.The jacket is made of halogen-free, flame-retardant material in accordance with IEC60332-1, IEC60754-2, IEC61034, EN50399 and Eurobrand class Dca s1 d1 a1. The shielding meets the separation class D according to EN50174 with a coupling attenuation of 85 dB. The cable is future-proof for all applications according to class C, D and E and suitable for the operation of PoE and PoE+ over a channel length according to class C, D and E up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet and Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T or up to 1,000 Mbit/s.
| Property | Value |
| Number of cores: | 16 |
| Outer diameter approx.: | 4.7 mm |
| AWG cross-section: | 26 |
| Conductor class: | Cl.1 = single-wire |
| Stranding element: | Pairs |
| Core marking: | Color |
| Shield over stranding element: | Foil |
| Category: | 7 |
| Flame-retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | yes |
| Sheath color: | white |
| Conductor nominal cross-section: | 0.14 mm² |
| Conductor diameter: | 0.42 mm |
| Stranding: | Layers |
| Material of the core insulation: | Polyolefins |
| Number of stranding elements: | 8 |
| Shield over stranding: | Braid |
| Conductor surface: | bare |
| Protective jacket: | no |
| Reinforcement: | no |
| Jacket material: | Polyolefins |
| Halogen-free according to EN 60754-1/2: | yes |
| Halogen-free according to IEC 60754-2: | yes |
| Low smoke according to IEC 61034-2: | yes |
| Oil-resistant according to EN 60811-404: | no |
| Oil-resistant according to IEC 60811-404: | no |
| Functional integrity: | no |
| Permissible external cable temperature during assembly/handling: | 0 to 50 °C |
| Permissible Cable external temperature after installation without vibration: | -20 to 60 °C |
| NVP value: | 79 % |
| Specification of core insulation: | Polyethylene (PE) |
| Cable longitudinally watertight: | no |
| Cable transversely watertight: | no |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | Dca |
| Smoke development class according to EN 13501-6: | s1 |
| Drip behavior class according to EN 13501-6: | d1 |
| Acid development class according to EN 13501-6: | a1 |
| Min. permissible bending radius, flexible use with forced guidance: | 47 mm |
| Min. permissible bending radius, flexible use/free movement: | 28 mm |
| Min. permissible bending radius, stationary use/fixed installation: | 28 mm |
| Laying in the ground: | no |
| UV-resistant: | no |