Draka installation cable for indoor use UC HOME SS26 Cat.7 S/FTP 4P LSHF DcaCat.7 copper data cable for structured cabling with a bandwidth of 600 MHz.With foil pair shielding and high-quality braided cover, the cable is double shielded.The 4-pair simplex installation cable with 8 copper wires AWG26 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted.The product exceeds the requirements of EN50173-1, EN50288-4-2, ISO/IEC11801, IEC61156-6 and IEEE802.3 af/at/bt.The jacket is made of halogen-free, flame-retardant material in accordance with IEC60332-1, IEC60754-2, IEC61034, EN50399 and Eurofire class Dca s2 d2 a1.The shielding meets the separation class D according to EN50174 with a coupling attenuation of 85 dB.The cable is future-proof for all applications according to class C, D, and E and suitable for operating PoE and PoE+ over a channel length according to class C, D, and E up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet and Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T or up to 1,000 Mbit/s.
Property | Value |
Number of cores: | 8 |
Outer diameter approx.: | 5.8 mm |
AWG cross-section: | 26 |
Conductor class: | Cl.1 = single-wire |
Stranding element: | pairs |
Core marking: | Color |
Shield over stranding element: | foil |
Category: | 7 |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | yes |
Sheath colour: | white |
Nominal conductor cross-section: | 0.14 mm² |
Conductor diameter: | 0.42 mm |
Stranding: | Layers |
Material of the core insulation: | Polyolefins |
Number of stranding elements: | 4 |
Shield over Stranding: | Braid |
Conductor surface: | bare |
Protective jacket: | no |
Reinforcement: | no |
Jacket material: | Polyolefins |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Functional integrity: | no |
Permissible external cable temperature during assembly/handling: | 0 to 50 °C |
Permissible Cable external temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 79 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Dca |
Smoke development class according to EN 13501-6: | s2 |
Drip behavior class according to EN 13501-6: | d2 |
Acid development class according to EN 13501-6: | a1 |
Min. permissible bending radius, flexible use with forced guidance: | 50 mm |
Min. permissible bending radius, flexible use/free movement: | 25 mm |
Min. permissible bending radius, stationary use/fixed installation: | 25 mm |
Laying in the ground: | no |
UV-resistant: | no |