Draka installation cable for indoor use UC1500 HS22 Cat.7A S/FTP 2x4P LSHF Dca copper data cable of Cat.7A for structured cabling with a bandwidth of 1500 MHz. The cable is double shielded with foil pair shielding and high-quality braided cover. The 2x4-pair duplex installation cable with 2x8 copper wires AWG22 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted. The product exceeds the requirements of EN50173-1, EN50288-9-1, ISO/IEC11801, IEC61156-5, IEC61156-7 and IEEE802.3 af/at/bt. The jacket is made of halogen-free, flame-retardant material in accordance with IEC60332-1, IEC60754-2, IEC61034, EN50399 and Eurofire class Dca s2 d1 a1. The shielding meets separation class D in accordance with EN50174 with a coupling attenuation of 80 dB. The cable is future-proof for all applications in accordance with classes C, D, E, EA, F and FA and is suitable for operating PoE and PoE+ over a channel length of up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet, Gigabit Ethernet and 10Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T, 10GBaseT and 25GBaseT up to 30m.
Property | Value |
Number of cores: | 16 |
AWG cross-section: | 22 |
Conductor class: | Cl.1 = single wire |
Stranding element: | Pairs |
Core marking: | Color |
Shield over stranding element: | Foil |
Category: | 7A (IEC) |
Flame retardant: | according to EN 60332-3-24 |
Low smoke according to EN 61034-2: | yes |
Sheath color: | yellow |
Conductor nominal cross-section: | 0.3 mm² |
Conductor diameter: | 0.62 mm |
Stranding: | Layers |
Material of core insulation: | Polyolefins |
Number of stranding elements: | 8 |
Shield over stranding: | Braid |
Conductor surface: | bare |
Protective sheath: | no |
Reinforcement: | no |
Sheath material: | Polyolefins |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Functional integrity: | no |
Perm. External cable temperature during assembly/handling: | 0 to 50 °C |
Permissible Cable external temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 79 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Dca |
Smoke development class according to EN 13501-6: | s2 |
Drip behavior class according to EN 13501-6: | d1 |
Acid development class according to EN 13501-6: | a1 |
Min. permissible bending radius, flexible use with forced guidance: | 68 mm |
Min. permissible bending radius, flexible use/free movement: | 40 mm |
Min. permissible bending radius, stationary use/fixed installation: | 40 mm |
Laying in the ground: | no |
UV-resistant: | no |