Installation cable for indoor useCopper data cable of category Cat. 7A for structured cabling with a bandwidth of 1500 MHz. The cable is double shielded with foil pair shielding and high-quality braided cover. The 4-pair simplex installation cable with 8 copper cores AWG22 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted. Exceeds the requirements of EN 50173-1, EN50288-9-1, ISO/IEC 11801, IEC 61156-5 and IEEE 802.3 af/at/bt. The jacket is made of halogen-free, flame-retardant material in accordance with Eurofire class Cca s1d1a1. With a coupling attenuation of 85 dB, the shielding meets separation class D in accordance with EN50174. The cable is future-proof for all applications according to class C, D, E, EA, F and FA and suitable for operating PoE and PoE+ over a channel length according to class C, D, E, EA, F and FA up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet, Gigabit Ethernet and 10Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T, 10GBaseT or up to 10,000 Mbit/s. The cable has the following validated: 3P Certification Program NVP: 79 Cu number: 40, 4 Color: yellow
Property | Value |
Number of cores: | 8 |
Outer diameter approx.: | 7.6 mm |
AWG cross-section: | 22 |
Conductor class: | Cl.1 = single-wire |
Stranding element: | Pairs |
Core marking: | Color |
Shield over stranding element: | Foil |
Category: | 7A (IEC) |
Flame-retardant: | according to EN 60332-3-24 |
Low smoke according to EN 61034-2: | yes |
Sheath color: | yellow |
Conductor nominal cross-section: | 0.3 mm² |
Conductor diameter: | 0.62 mm |
Stranding: | Layers |
Material of the core insulation: | Polyolefins |
Number of stranding elements: | 4 |
Shield over stranding: | Braid |
Conductor surface: | bare |
Protective jacket: | no |
Jacket material: | Polyolefines |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Functional integrity: | no |
Perm. External cable temperature during assembly/handling: | 0 to 50 °C |
Permissible Cable external temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 79 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Cca |
Smoke development class according to EN 13501-6: | s1a |
Drip behavior class according to EN 13501-6: | d1 |
Acid development class according to EN 13501-6: | a1 |
Min. permissible bending radius, flexible use with forced guidance: | 76 mm |
Min. permissible bending radius, flexible use/free movement: | 45 mm |
Min. permissible bending radius, stationary use/fixed installation: | 45 mm |
Laying in the ground: | no |
UV-resistant: | no |