Draka UC900: Band-safe, flexible, packing-tightThe high-quality copper installation cable Draka UC900 SS23 Cat.7 S/FTP Cca s1a d1 a1 for structured building cabling offers the highest level of fire protection in accordance with the EU Construction Products Regulation (CPR) thanks to a halogen-free, flame-retardant sheath material with an extremely low smoke development density (class s1a). The small outer diameter of 7.3 mm ensures a high packing density. Highly flexible, tight bending radii enable the copper cables to be laid easily. The Draka UC900 transmits data at a speed of 10 Gbit/s and a bandwidth of 1000 MHz. Further features: Optimally shielded installation and connection cable in separation class 'd' (EN50174-2), highest shielding class for coupling attenuation Type I and coupling resistance Grade 1 (EMC regulations), future-proof for all applications according to classes C, D, E, EA and F.
Property | Value |
Number of cores: | 8 |
Outer diameter approx.: | 7.3 mm |
AWG cross-section: | 23 |
Conductor class: | Cl.1 = single-wire |
Stranding element: | pairs |
Core marking: | Color |
Shield over stranding element: | foil |
Category: | 7 |
Flame-retardant: | according to EN 60332-3-24 |
Low smoke according to EN 61034-2: | yes |
Sheath colour: | orange |
Conductor nominal cross-section: | 0.25 mm² |
Conductor diameter: | 0.56 mm |
Stranding: | Layers |
Material of core insulation: | Polyolefins |
Number of stranding elements: | 4 |
Shield over Stranding: | Braid |
Conductor surface: | bare |
Protective jacket: | no |
Reinforcement: | no |
Jacket material: | Polyolefins |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Insulation integrity according to IEC 60331: | no |
Functional integrity: | no |
Permissible external cable temperature during assembly/handling: | 0 to 50 °C |
Permissible Cable external temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 79 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Cca |
Smoke development class according to EN 13501-6: | s1a |
Drip behavior class according to EN 13501-6: | d1 |
Acid development class according to EN 13501-6: | a1 |
Min. permissible bending radius, flexible use with forced guidance: | 60 mm |
Min. permissible bending radius, stationary use/fixed installation: | 30 mm |
Laying in the ground: | no |
UV-resistant: | no |