Draka installation cable for indoor use UC900 HS23 Cat.7 S/FTP 4P LSHF Eca Cat.7 copper data cable for structured cabling with a bandwidth of 1000 MHz.With foil pair shielding and high-quality braided cover, the cable is double shielded.The 4-pair simplex installation cable with 8 copper wires AWG23 is suitable for connecting sockets, patch panels and modules, also with LSA technology, for installation in buildings, in ducts and flush-mounted.The product exceeds the requirements of EN50173-1, EN50288-4-1, ISO/IEC11801, IEC61156-5 and IEEE802.3 af/at/bt.The jacket is made of halogen-free, flame-retardant material in accordance with IEC60332-1, IEC60754-2, IEC61034, EN50399 and Eurofire class Eca.The shielding meets the separation class D according to EN50174 with a coupling attenuation of 80 dB.The cable is future-proof for all applications according to classes C, D, E, EA and F and suitable for the operation of PoE and PoE+ over a channel length of up to 100m. It is suitable for the following transmissions: telephony, Ethernet, Fast Ethernet, Gigabit Ethernet and 10Gigabit Ethernet, 10BaseT, 100BaseT, 1000BaseT, 1GBase-T, 10GBaseT or up to 10,000 Mbit/s.
Property | Value |
Number of cores: | 8 |
Outer diameter approx.: | 7.3 mm |
AWG cross-section: | 23 |
Conductor class: | Cl.1 = single-wire |
Stranding element: | pairs |
Core marking: | Color |
Shield over stranding element: | foil |
Category: | 7 |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | yes |
Sheath colour: | orange |
Conductor nominal cross-section: | 0.25 mm² |
Conductor diameter: | 0.56 mm |
Stranding: | Layers |
Material of core insulation: | Polyolefins |
Number of stranding elements: | 4 |
Shield over Stranding: | Braid |
Conductor surface: | bare |
Protective jacket: | no |
Reinforcement: | no |
Jacket material: | Polyolefins |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Functional integrity: | no |
Permissible external cable temperature during assembly/handling: | 0 to 50 °C |
Permissible External cable temperature after installation without vibration: | -20 to 60 °C |
NVP value: | 79 % |
Specification of core insulation: | Polyethylene (PE) |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Eca |
Min. permissible bending radius, flexible use with forced guidance: | 60 mm |
Min. permissible bending radius, stationary use/permanently installed: | 30 mm |
Laying in the ground: | no |
UV-resistant: | no |