Property | Value |
Overload release current setting: | 0.3 to 6.6 A |
Voltage type for actuation: | DC |
Main circuit connection type: | Plug connection |
Rated operating power at AC-3, 400 V: | 3 kW |
Rated operating current Ie: | 6.6 A |
With short-circuit release: | yes |
Protection class (IP): | IP65 |
Supports protocol for SafetyBUS p: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for CAN: | no |
Supports protocol for ASI: | yes |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for Data-Highway: | no |
Supports protocol for MODBUS: | no |
Trigger class: | CLASS 10 A |
Supports protocol for PROFINET IO: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for SERCOS: | no |
Temperature compensated overload protection: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | no |
Supports protocol for PROFINET CBA: | no |
Type of motor starter: | Direct starter |
Rated operating current at AC-3, 400 V: | 6.6 A |
Supports protocol for SUCONET: | no |
Rail mounting possible: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for LON: | no |
Supports protocol for DeviceNet Safety: | no |
Ambient temperature, upper limit without restrictions: | 55 °C |
Conditional rated short-circuit current, allocation type 1, 480 Y/277 V: | 65000 A |
Supports protocol for PROFIBUS: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for INTERBUS-Safety: | no |
Rated power, 460 V, 60 Hz, 3-phase: | 2,238 kW |
With transformer: | no |
Number of command points: | 1 |
Suitable for EMERGENCY STOP: | no |
Assignment type according to IEC 60947-4-3: | Class 1 |
External reset possible: | yes |
With fuse: | no |
Protection class (NEMA): | 12 |
Width: | 220 mm |
Height: | 270 mm |
Depth: | 120 mm |
Features
With fuse
No
Rated operating current Ie
6.6 A
External reset possible
Yes
With transformer
No
Type of motor starter
Direct starter
Rated operating current at AC-3, 400 V
6.6 A
With short-circuit release
Yes
Temperature-compensated overload protection
Yes
Ambient temperature, upper limit without restrictions
55 °C
Assignment type according to IEC 60947-4-3
Class 1
HAB
RAMO5-D202A32-5120S1 6.6A 230/277VAC
Manufacturer
HAN
198521
GTIN
4015081963966
Connection type main circuit
Plug connection
Number of command posts
1
Trigger class
CLASS 10 A
Rated operational power at AC-3, 400 V
3kW
Width
220 mm
Suitable for EMERGENCY STOP
No
Height
270 mm
IP protection)
IP65
Protection class (NEMA)
12
Voltage type for actuation
DC
Depth
120 mm
Mounting rail possible
No
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
Yes
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
No
Overload release current setting
0.3 to 6.6A