Description
Features
Reviews
Functional element, connection to SmartWire-DT: yes, can be used for: DILM(C)7. - DILM(C)32., DILM38., DILA., DILMP20., DILMP32., DILMP45., MSC-D(E)-...(24VDC)
Property | Value |
Protection class (IP): | IP20 |
Output current: | 0.5 A |
Type of supply voltage: | DC |
Permissible voltage at input: | 15 V |
Input current for signal 1: | 3 mA |
Width: | 45 mm |
Height: | 38 mm |
Depth: | 72 mm |
Rail mounting possible: | no |
Radio standard Bluetooth: | no |
Type of digital output: | without |
Wireless standard WLAN 802.11: | no |
Supports protocol for INTERBUS: | no |
Design of the electrical connection: | spring-loaded connection |
Performance level according to EN ISO 13849-1: | without |
Supports protocol for PROFIBUS: | no |
Supports protocol for ASI: | no |
Rack mounting possible: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for PROFINET CBA: | no |
Supply voltage for DC: | 15 V |
Supports protocol for Data-Highway: | no |
Permissible voltage at output: | 20.4 to 28.8 V |
Supports protocol for SafetyBUS p: | no |
IO-Link Master: | no |
Supports protocol for MODBUS: | no |
Wall/direct mounting possible: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | yes |
Supports protocol for SERCOS: | no |
Supports protocol for KNX: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SUCONET: | no |
Front installation possible: | no |
Suitable for safety functions: | no |
Supports protocol for TCP/IP: | no |
Type of output voltage: | DC |
Supports protocol for CAN: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Type of input voltage: | DC |
Delay time for signal change: | 10 to 84 ms |
Short-circuit protection, outputs available: | no |
Fieldbus connection via separate bus coupler possible: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
Number of other HW interfaces: | 1 |
With optical interface: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Wireless standard GSM: | no |
Number of digital inputs: | 2 |
Digital inputs configurable: | no |
Wireless standard GPRS: | no |
Number of digital outputs: | 1 |
SIL according to IEC 61508: | without |
Digital outputs configurable: | no |
Wireless standard UMTS: | no |
Features
Type of voltage of the supply voltage
DC
Supports protocol for KNX
No
With optical interface
No
Output current
0.5 A
HAB
DIL-SWD-32-002
Manufacturer
HAN
118561
GTIN
4015081168316
Design of the electrical connection
Spring-loaded connection
Width
45 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
38 mm
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
72 mm
Mounting rail possible
No
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
Yes
No reviews yet — your comment may be first.
All reviews 0