Description
Features
Reviews
Input/output extension for the easyE4 series control relays with a rated operating voltage of 100 - 240 VAC or 100 - 240 VDC. For cULus, 100-110 V DC applies to all V DC specifications. This extension provides 8 digital inputs for 100 - 240VAC or 100 - 240 VDC and 8 relay outputs for 12 - 250 VAC or 12-220 VDC. The connections are made via screw terminals. The connection to the easy-E4 control relay or another easy-E4 extension is made using the easy-E4-CONNECT1 connector plug (item Y7-197225) which is included in the scope of delivery.
Property | Value |
Number of digital outputs: | 8 |
Number of digital inputs: | 8 |
Supply voltage at AC 50 Hz: | 85 to 264 V |
Supply voltage at AC 60 Hz: | 85 to 264 V |
Supply voltage at DC: | 110 to 220 V |
Protection class (IP): | IP20 |
Switching current: | 5 A |
Height: | 90 mm |
Width: | 72 mm |
Depth: | 58 mm |
Performance Level according to EN ISO 13849-1: | without |
With relay output: | yes |
Type of supply voltage: | AC |
Expandable: | yes |
With timer: | no |
With display: | no |
Wall/direct mounting possible: | yes |
Front installation possible: | yes |
DIN rail mounting possible: | yes |
Rack mounting possible: | no |
Wireless standard Bluetooth: | no |
Wireless standard WLAN 802.11: | no |
Suitable for safety functions: | no |
Basic device: | no |
Extension device: | yes |
IO-Link Master: | no |
With optical interface: | no |
Supports protocol for SERCOS: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for INTERBUS: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for SafetyBUS p: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for Data-Highway: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for TCP/IP: | yes |
Supports protocol for other bus systems: | no |
Supports protocol for MODBUS: | yes |
Supports protocol for SUCONET: | no |
Supports protocol for CAN: | no |
Supports protocol for ASI: | no |
Supports protocol for PROFINET CBA: | no |
Supports protocol for KNX: | no |
Supports protocol for LON: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for INTERBUS-Safety: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Redundancy capability: | no |
Radio standard GPRS: | no |
SIL according to IEC 61508: | without |
Wireless standard GSM: | no |
Wireless standard UMTS: | no |
Features
Type of voltage of the supply voltage
AC
Supports protocol for KNX
No
With optical interface
No
HAB
EASY-E4-AC-16RE1
Manufacturer
HAN
197222
GTIN
4015081939428
Width
72 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
90 mm
With display
No
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
58 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
Yes
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
Yes
Supports protocol for other bus systems
No
No reviews yet — your comment may be first.
All reviews 0