Description
Features
Reviews
SmartWire-DT device for connecting digital input/output signals, automatic address setting, module with 4 digital inputs 24VDC, 2 digital relay outputs 250VAC, 3A, connection with push-in terminals
Property | Value |
Protection class (IP): | IP20 |
Output current: | 3 A |
Type of supply voltage: | AC |
Permissible voltage at input: | 20.4 to 28.8 V |
Input current for signal 1: | 4 mA |
Width: | 35 mm |
Height: | 90 mm |
Depth: | 102 mm |
Mounting rail mounting possible: | yes |
Wireless standard Bluetooth: | no |
Type of digital output: | relay |
Wireless standard WLAN 802.11: | no |
Supports protocol for INTERBUS: | no |
Design of the electrical connection: | flat plug connection |
Performance level according to EN ISO 13849-1: | without |
Supports protocol for PROFIBUS: | no |
Supports protocol for ASI: | no |
Rack mounting possible: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFIsafe: | no |
Supports protocol for PROFINET CBA: | no |
Supply voltage for DC: | 0 to 28.8 V |
Supports protocol for Data-Highway: | no |
Permissible voltage at output: | 0 to 250 V |
Supports protocol for SafetyBUS p: | no |
IO-Link Master: | no |
Supports protocol for MODBUS: | no |
Wall/direct mounting possible: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | yes |
Supports protocol for SERCOS: | no |
Supports protocol for KNX: | no |
Supports protocol for DeviceNet Safety: | no |
Supports protocol for SUCONET: | no |
Front installation possible: | no |
Suitable for safety functions: | no |
Supports protocol for TCP/IP: | no |
Type of output voltage: | AC |
Supports protocol for CAN: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Type of input voltage: | AC |
Short-circuit protection, outputs available: | no |
Fieldbus connection possible via separate bus coupler: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
With optical interface: | no |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | without |
Explosion protection category for dust: | without |
Wireless standard GSM: | no |
Number of digital Inputs: | 4 |
Digital inputs configurable: | no |
Wireless standard GPRS: | no |
Number of digital outputs: | 2 |
SIL according to IEC 61508: | without |
Digital outputs configurable: | no |
Wireless standard UMTS: | no |
Features
Type of voltage of the supply voltage
AC
Supports protocol for KNX
No
With optical interface
No
Output current
3 A
HAB
EU5E-SWD-4D2R
Manufacturer
HAN
116383
GTIN
4015081161133
Design of the electrical connection
Flat plug connection
Width
35 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
90 mm
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Depth
102 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
Yes