Description
Features
Reviews
SmartWire-DT device for connecting analog input signals, automatic address setting, module with 4 temperature inputs Pt100 / Pt1000: -50 - +200°C, Ni1000: -50 - +150 °C, 2/3-wire connection, individually configurable, connection with push-in terminals
Property | Value |
Protection class (IP): | IP20 |
Type of supply voltage: | DC |
Height: | 90 mm |
Width: | 35 mm |
Depth: | 102 mm |
Input, current: | no |
Input, voltage: | no |
Output, current: | no |
Output, voltage: | no |
Supports protocol for SafetyBUS p: | no |
Wireless standard WLAN 802.11: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for KNX: | no |
Supports protocol for MODBUS: | no |
Supports protocol for PROFIsafe: | no |
Wall/direct mounting possible: | yes |
Supports protocol for EtherNet/IP: | no |
Front installation possible: | no |
Supports protocol for TCP/IP: | no |
Design of the electrical connection: | Flat plug connection |
Rack mounting possible: | no |
Supports protocol for SUCONET: | no |
Performance level according to EN ISO 13849-1: | without |
Resolution of the analog inputs: | 12 bit |
Supports protocol for INTERBUS: | no |
Supports protocol for DeviceNet Safety: | no |
Wireless standard Bluetooth: | no |
Supports protocol for PROFIBUS: | no |
Suitable for safety functions: | no |
Supports protocol for CAN: | no |
Supports protocol for SERCOS: | no |
IO-Link Master: | no |
Supports protocol for ASI: | no |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for PROFINET CBA: | no |
Supports protocol for data highway: | no |
Supports protocol for other bus systems: | yes |
Input, resistance: | no |
Input, resistance thermometer: | yes |
Input, thermocouple: | no |
Input signal configurable: | no |
Output signal configurable: | no |
Mounting rail mounting possible: | yes |
Field bus connection possible via separate bus coupler: | yes |
Supports protocol for LON: | no |
Supports protocol for INTERBUS-Safety: | no |
System component: | yes |
Associated equipment (Ex ia): | no |
Associated equipment (Ex ib): | no |
Explosion protection category for gas: | none |
Explosion protection category for dust: | none |
Analog inputs configurable: | yes |
Number of analog inputs: | 4 |
Wireless standard GSM: | no |
Wireless standard GPRS: | no |
SIL according to IEC 61508: | without |
Analog outputs configurable: | yes |
Wireless standard UMTS: | no |
Protection class (NEMA): | 1 |
Features
Type of voltage of the supply voltage
DC
Supports protocol for KNX
No
HAB
EU5E-SWD-4PT
Manufacturer
HAN
144064
GTIN
4015081405947
Design of the electrical connection
Flat plug connection
Width
35 mm
Explosion protection category for gas
Without
Explosion protection category for dust
Without
Suitable for security functions
No
Height
90 mm
Performance Level according to EN ISO 13849-1
Without
SIL according to IEC 61508
Without
IP protection)
IP20
Protection class (NEMA)
1
Depth
102 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
Yes
No reviews yet — your comment may be first.