High-quality residual current circuit breaker/circuit breaker combination independent of mains voltage, contact position indicator red-green, clamping aid - rear plug protection, tri-stable locking slide - enables removal from an existing busbar assembly, extensive range of accessories can be retrofitted, large selection of rated residual currents, rated currents up to 40A, tripping characteristics B, C, D, rated switching capacity 10kA, suitable for use outdoors (construction site power and outdoor distributors) down to -25°C
Property | Value |
Tripping characteristic: | C |
Rated current: | 5 A |
Rated voltage: | 230 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 1 |
Number of poles (total): | 1 |
Energy limitation class: | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 70.5 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 15 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 15 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 10 kA |
Pollution level: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 1 |
Rated insulation voltage Ui: | 440 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Ambient temperature during operation: | -25 to 75 °C |
Connectable conductor cross-section, stranded: | 1 to 25 mm² |
Connectable conductor cross-section, single-wire: | 1 to 25 mm² |
Features
HAB
FAZ-C5/1 5A 1-pole
Manufacturer
HAN
278554
GTIN
4015082785543
Connectable conductor cross-section solid
1 to 25 mm²
Connectable conductor cross-section stranded
1 to 25 mm²
Number of protected poles
1
Trigger characteristics
C
Rated insulation voltage Ui
440V
Rated switching capacity Icn according to EN 60898 at 230 V
10kA
Rated switching capacity Icn according to EN 60898 at 400 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
15kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
15kA
Rated voltage
230V
Rated impulse withstand voltage Uimp
4kV
Rated current
5A
Width in pitch units
1
Installation depth
70.5 mm
Energy limitation class
3
Frequency
50 to 60 Hz
Switching neutral conductor
No
Number of poles (total)
1
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 75 °C
Degree of contamination
2
Additional equipment possible
Yes
Overvoltage category
3