Description
Features
Reviews
High-quality residual current circuit breaker/circuit breaker combination independent of mains voltage, contact position indicator red-green, clamping aid - rear plug protection, tri-stable locking slide - enables removal from an existing busbar system, extensive range of accessories can be retrofitted, large selection of rated residual currents, rated currents up to 40A, tripping characteristics B, C, D, rated switching capacity 10kA, suitable for use outdoors (construction site power and outdoor distribution) down to -25°C
Property | Value |
Tripping characteristic: | B |
Rated current: | 16 A |
Rated residual current: | 0.03 A |
Rated voltage: | 240 V |
Frequency: | 50 Hz |
Number of poles (total): | 2 |
Width in pitch units: | 2 |
Residual current type: | A |
Installation depth: | 70 mm |
Surge current strength: | 3 kA |
Degree of protection (IP): | IP20 |
Energy limitation class: | 3 |
Overvoltage category: | 3 |
Pollution degree: | 2 |
Switching neutral conductor: | yes |
Number of protected poles: | 1 |
Type of voltage: | AC |
False tripping protection: | yes |
Rated insulation voltage Ui: | 250 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Rated breaking capacity according to EN 61009: | 10 kA |
Rated short-circuit breaking capacity Icn according to EN 61009-1: | 10 kA |
Shutdown characteristics: | short-time delayed |
With locking device: | no |
Ambient temperature during operation: | -25 to 40 °C |
Connectable conductor cross-section, single-wire: | 1 to 25 mm² |
Connectable conductor cross-section, stranded: | 1 to 25 mm² |
Features
Shutdown characteristics
Short-term delayed
Rated short-circuit breaking capacity Icn according to EN 61009-1
10 kA
HAB
FI/LS 16A 30mA LS characteristic curve B 1p
Manufacturer
HAN
168266
GTIN
4015081648450
Connectable conductor cross-section solid
1 to 25 mm²
Connectable conductor cross-section stranded
1 to 25 mm²
Number of protected poles
1
Trigger characteristics
B
Rated breaking capacity according to EN 61009
10kA
Rated residual current
0.03A
Rated insulation voltage Ui
250V
Rated voltage
240V
Rated impulse withstand voltage Uimp
4kV
Rated current
16A
Width in pitch units
2
Installation depth
70 mm
Energy limitation class
3
False trigger protection
Yes
Residual current type
A
Frequency
50Hz
With locking device
No
Switching neutral conductor
Yes
Number of poles (total)
2
IP protection)
IP20
Voltage type
AC
Surge current strength
3kA
Ambient temperature during operation
-25 to 40 °C
Degree of contamination
2
Overvoltage category
3