Description
Features
Reviews
High-quality residual current circuit breaker/circuit breaker combination independent of mains voltage, contact position indicator red-green, clamping aid - rear plug protection, tri-stable locking slide - enables removal from an existing busbar assembly, extensive range of accessories can be retrofitted, large selection of rated residual currents, rated currents up to 40A, tripping characteristics B, C, D, rated switching capacity 10kA, suitable for use outdoors (construction site power and outdoor distributors) down to -25°C
Property | Value |
Tripping characteristic: | B |
Rated current: | 16 A |
Rated residual current: | 0.03 A |
Rated voltage: | 415 V |
Frequency: | 50 Hz |
Number of poles (total): | 4 |
Width in pitch units: | 4 |
Residual current type: | A |
Installation depth: | 75.5 mm |
Surge current strength: | 0.25 kA |
Protection class (IP): | IP20 |
Energy limitation class: | 3 |
Overvoltage category: | 3 |
Pollution degree: | 2 |
Switching neutral conductor: | yes |
Number of protected poles: | 4 |
Voltage type: | AC |
False tripping protection: | no |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Rated breaking capacity according to EN 61009: | 6 kA |
Rated short-circuit breaking capacity Icn according to EN 61009-1: | 6 kA |
Shutdown characteristics: | instantaneous |
With locking device: | no |
Ambient temperature during operation: | -25 to 40 °C |
Connectable conductor cross-section, single-wire: | 1 to 25 mm² |
Connectable conductor cross-section, stranded: | 1 to 25 mm² |
Features
Shutdown characteristics
Without delay
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
HAB
FRBM6-B16/3N/003-A 3-pin+N 16A 30mA
Manufacturer
HAN
170988
GTIN
4015081671113
Connectable conductor cross-section solid
1 to 25 mm²
Connectable conductor cross-section stranded
1 to 25 mm²
Number of protected poles
4
Trigger characteristics
B
Rated breaking capacity according to EN 61009
6kA
Rated residual current
0.03A
Rated insulation voltage Ui
500V
Rated voltage
415V
Rated impulse withstand voltage Uimp
4kV
Rated current
16A
Width in pitch units
4
Installation depth
75.5 mm
Energy limitation class
3
False trigger protection
No
Residual current type
A
Frequency
50Hz
With locking device
No
Switching neutral conductor
Yes
Number of poles (total)
4
IP protection)
IP20
Voltage type
AC
Surge current strength
0.25kA
Ambient temperature during operation
-25 to 40 °C
Degree of contamination
2
Overvoltage category
3
No reviews yet — your comment may be first.
All reviews 0