+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Eaton FRBMM-B16/1N/003-G/A residual current circuit breaker, 170717

Brand:Eaton
To compare
To favorites
SKU:479897
Eaton FRBMM-B16/1N/003-G/A residual current circuit breaker, 170717
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
HAB
Manufacturer
In stock
€91.85
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

High-quality residual current circuit breaker/circuit breaker combination independent of mains voltage, contact position indicator red-green, clamping aid - rear plug protection, tri-stable locking slide - enables removal from an existing busbar assembly, extensive range of accessories can be retrofitted, large selection of rated residual currents, rated currents up to 40A, tripping characteristics B, C, D, rated switching capacity 10kA, suitable for use outdoors (construction site power and outdoor distributors) down to -25°C

PropertyValue
Tripping characteristic:B
Rated current:16 A
Rated residual current:0.03 A
Rated voltage:240 V
Frequency:50 Hz
Number of poles (total):2
Width in modular spacing:2
Residual current type:A
Installation depth:75.5 mm
Rated breaking capacity according to IEC 60947-2:15 kA
Surge current strength:3 kA
Protection class (IP):IP20
Energy limitation class:3
Overvoltage category:3
Pollution degree:2
Switching neutral conductor:yes
Number of protected poles:1
Voltage type:AC
False tripping protection:yes
Rated insulation voltage Ui:500 V
Rated impulse withstand voltage Uimp:4 kV
Rated breaking capacity according to EN 61009:10 kA
Rated short-circuit breaking capacity Icn according to EN 61009-1:10 kA
Shutdown characteristics:short-time delayed
With locking device:no
Ambient temperature during operation:-25 to 40 °C
Connectable conductor cross-section, single-wire:1 to 25 mm²
Connectable Stranded conductor cross-section:1 to 25 mm²
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
HAB
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated breaking capacity according to EN 61009
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Eaton FAZ-C20/2 circuit breaker, 278761
Eaton FAZ-C20/2 circuit breaker, 278761
91.85
In stock
Eaton SL4-PIB-T-250 base module, 250 mm aluminum tube, 171306
Eaton SL4-PIB-T-250 base module, 250 mm aluminum tube, 171306
91.82
In stock
Eaton SL7-CB-T-100 base module, 100 mm aluminum tube, 171452
Eaton SL7-CB-T-100 base module, 100 mm aluminum tube, 171452
91.82
In stock
Eaton XPBMB0604-ROT pivoting 600x425mm partition wall, 112312
Eaton XPBMB0604-ROT pivoting 600x425mm partition wall, 112312
91.80
In stock
Eaton FAZ-B32/3 circuit breaker, 278850
Eaton FAZ-B32/3 circuit breaker, 278850
91.91
In stock