Description
Features
Reviews
Open load-break switch, load-break switch, number of poles 3-pole, rated current = rated continuous current 800 A, protective function without protection, standard/approval IEC, installation technology fixed installation
Property | Value |
Number of poles: | 3 |
Number of auxiliary contacts as changeover contacts: | 2 |
Rated continuous current Iu: | 800 A |
Max. Rated operating voltage Ue at AC: | 690 V |
Emergency stop device design: | no |
Protection class (IP), front: | IP31 |
Main circuit connection type: | Rail connection |
Device design: | Built-in device, fixed installation technology |
Design of the actuating element: | Push button |
Suitable for floor mounting: | yes |
Conditional rated short-circuit current Iq: | 88 kA |
Integrated motor drive: | no |
Suitable for front mounting 4-hole: | no |
Version as maintenance/repair switch: | yes |
Voltage release optional: | yes |
Suitable for front mounting central: | no |
Suitable for intermediate installation: | yes |
Suitable for distribution board installation: | yes |
Version as main switch: | yes |
Version as safety switch: | no |
Motor drive optional: | yes |
Lockable: | yes |
Version as reversing switch: | no |
Rated short-time withstand current Icw: | 42 kA |
Color of the actuating element: | green |
Rated operating voltage: | 690 V |
Number of switches: | 1 |
Rated continuous current at AC-23, 400 V: | 800 A |
Features
Number of auxiliary contacts as changeover contacts
2
HAB
INX16B3-08F-1 3-pole 800A
Manufacturer
HAN
183448
GTIN
4015081791842
Connection type main circuit
Rail connection
Number of switches
1
Designed as main switch
Yes
Designed as an EMERGENCY STOP device
No
Designed as a safety switch
No
Designed as a maintenance/repair switch
Yes
Version as reversing switch
No
Design of the actuating element
Push button
Conditional rated short-circuit current Iq
88kA
Rated operating voltage
690V
Rated continuous current Iu
800A
Rated continuous current at AC-23, 400 V
800A
Rated short-time withstand current Icw
42kA
Color of the actuator
Green
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting Central
No
Suitable for distribution board installation
Yes
Suitable for intermediate construction
Yes
Device type
Built-in device Fixed installation technology
Max. rated operating voltage Ue at AC
690V
Motor drive integrated
No
Motor drive optional
Yes
Number of poles
3
Protection class (IP), front
IP31
Voltage release optional
Yes
Lockable
Yes
No reviews yet — your comment may be first.