Direct starter, basic device: MSC, overload release setting range: Ir= 8 - 32 A, actuating voltage: 24 V DC, direct current, standards and regulations: IEC/EN 60947-4-1,0660, UL, CSA
Property | Value |
Overload release current setting: | 8 to 32 A |
Voltage type for actuation: | DC |
Main circuit connection type: | Screw connection |
Rated operating power at AC-3, 400 V: | 15 kW |
Rated operating current Ie: | 29.3 A |
Rated control supply voltage Us at DC: | 24 V |
With short-circuit release: | yes |
Protection class (IP): | IP20 |
Supports protocol for SafetyBUS p: | no |
Number of auxiliary contacts as normally closed: | 1 |
Supports protocol for INTERBUS: | no |
Supports protocol for CAN: | no |
Supports protocol for ASI: | no |
Design of electrical connection for auxiliary and control circuit: | screw connection |
Supports protocol for Foundation Fieldbus: | no |
Supports protocol for Data Highway: | no |
Supports protocol for MODBUS: | no |
Trip class: | adjustable |
Supports protocol for PROFINET IO: | no |
Supports protocol for TCP/IP: | no |
Supports protocol for SERCOS: | no |
Temperature compensated overload protection: | yes |
Supports protocol for EtherNet/IP: | no |
Supports protocol for other bus systems: | yes |
Supports protocol for PROFINET CBA: | no |
Type of motor starter: | Direct starter |
Rated operating current at AC-3, 400 V: | 32 A |
Supports protocol for SUCONET: | no |
Mounting rail mounting possible: | yes |
Supports protocol for PROFIsafe: | no |
Supports protocol for DeviceNet: | no |
Supports protocol for LON: | no |
Supports protocol for DeviceNet Safety: | no |
Ambient temperature, upper limit without restrictions: | 55 °C |
Rated operating power at AC-3, 230 V, 3-phase: | 7.5 kW |
Supports protocol for PROFIBUS: | no |
Supports protocol for AS-Interface Safety at Work: | no |
Supports protocol for INTERBUS-Safety: | no |
Rated power, 460 V, 60 Hz, 3-phase: | 11 kW |
With transformer: | no |
Suitable for EMERGENCY STOP: | no |
Assignment type according to IEC 60947-4-3: | Class 2 |
External reset possible: | no |
With fuse: | no |
Protection class (NEMA): | other |
Width: | 45 mm |
Height: | 272 mm |
Depth: | 145 mm |
Features
With fuse
No
Rated operating current Ie
29.3 A
External reset possible
No
With transformer
No
Design of electrical connection for auxiliary and control circuit
Screw connection
Type of motor starter
Direct starter
Rated operating current at AC-3, 400 V
32 A
With short-circuit release
Yes
Temperature-compensated overload protection
Yes
Ambient temperature, upper limit without restrictions
55 °C
Rated operating power at AC-3, 230 V, 3-phase
7.5 kW
Assignment type according to IEC 60947-4-3
Class 2
HAB
MSC-DEA-32-M32-SP (24VDC)
Manufacturer
HAN
167825
GTIN
4015081644025
Connection type main circuit
Screw connection
Number of auxiliary contacts as normally closed
1
Trigger class
Adjustable
Rated operational power at AC-3, 400 V
15kW
Rated control supply voltage Us at DC
24V
Width
45 mm
Suitable for EMERGENCY STOP
No
Height
272 mm
IP protection)
IP20
Protection class (NEMA)
Other
Voltage type for actuation
DC
Depth
145 mm
Mounting rail possible
Yes
Supports protocol for AS-Interface Safety at Work
No
Supports protocol for ASI
No
Supports protocol for CAN
No
Supports data highway protocol
No
Supports protocol for DeviceNet
No
Supports protocol for DeviceNet Safety
No
Supports protocol for EtherNet/IP
No
Supports protocol for Foundation Fieldbus
No
Supports protocol for INTERBUS
No
Supports protocol for INTERBUS-Safety
No
Supports protocol for LON
No
Supports protocol for Modbus
No
Supports protocol for PROFIBUS
No
Supports protocol for PROFINET CBA
No
Supports protocol for PROFINET IO
No
Supports protocol for PROFIsafe
No
Supports protocol for SERCOS
No
Supports protocol for SUCONET
No
Supports protocol for SafetyBUS p
No
Supports protocol for TCP/IP
No
Supports protocol for other bus systems
Yes
Overload release current setting
8 to 32 A