Description
Features
Reviews
ON-OFF switch, Product range: ON-OFF switch, Type identifier: P1, with black toggle and front plate, Information on scope of delivery: Auxiliary switch contact or neutral conductor can be retrofitted., 3-pole, Protection class: Front IP30, Design: Distribution board installation, Rated operating power AC-23A, 50 - 60 Hz 400 V: P = 11 kW, Rated continuous current: Iu = 25 A, Standards and regulations: IEC/EN 60947,0660, IEC/EN 60204, CSA, UL, Load disconnector according to IEC/EN 60947-3
Property | Value |
Number of poles: | 3 |
Rated operating power at AC-23, 400 V: | 13 kW |
Number of auxiliary contacts as normally closed: | 1 |
Number of auxiliary contacts as normally open: | 1 |
Rated continuous current Iu: | 25 A |
Max. Rated operating voltage Ue at AC: | 690 V |
Version as EMERGENCY STOP device: | no |
Protection class (IP), front: | IP30 |
Connection type main circuit: | screw connection |
Device design: | Built-in device, fixed installation technology |
Design of the actuating element: | short rotary handle |
Suitable for floor mounting: | no |
Conditional rated short-circuit current Iq: | 50 kA |
Motor drive integrated: | no |
Suitable for front mounting 4-hole: | no |
Version as maintenance/repair switch: | no |
Voltage release optional: | no |
Suitable for front mounting central: | no |
Suitable for intermediate installation: | no |
Suitable for distribution board installation: | yes |
Version as main switch: | no |
Version as safety switch: | no |
Motor drive optional: | no |
Lockable: | no |
Version as reversing switch: | no |
Rated short-time withstand current Icw: | 0.64 kA |
Color of the actuating element: | black |
Rated operating voltage: | 690 V |
Rated operating power at AC-3, 400 V: | 7.5 kW |
Switching capacity at 400 V: | 13 kW |
Rated continuous current at AC-21, 400 V: | 25 A |
Number of Switch: | 1 |
Rated continuous current at AC-23, 400 V: | 25 A |
Protection class (NEMA): | other |
Features
HAB
P1-25/IVS/HI11
Manufacturer
HAN
053117
GTIN
4015080531173
Connection type main circuit
Screw connection
Number of auxiliary contacts as normally open
1
Number of auxiliary contacts as normally closed
1
Number of switches
1
Designed as main switch
No
Designed as an EMERGENCY STOP device
No
Designed as a safety switch
No
Designed as a maintenance/repair switch
No
Version as reversing switch
No
Design of the actuating element
Short twist grip
Conditional rated short-circuit current Iq
50kA
Rated operational power at AC-23, 400 V
13kW
Rated operational power at AC-3, 400 V
7.5kW
Rated operating voltage
690V
Rated continuous current Iu
25A
Rated continuous current at AC-21, 400 V
25A
Rated continuous current at AC-23, 400 V
25A
Rated short-time withstand current Icw
0.64kA
Color of the actuator
Black
Suitable for floor mounting
No
Suitable for front mounting 4-hole
No
Suitable for front mounting Central
No
Suitable for distribution board installation
Yes
Suitable for intermediate construction
No
Device type
Built-in device Fixed installation technology
Max. rated operating voltage Ue at AC
690V
Motor drive integrated
No
Motor drive optional
No
Number of poles
3
Switching capacity at 400 V
13kW
Protection class (IP), front
IP30
Protection class (NEMA)
Other
Voltage release optional
No
Lockable
No
No reviews yet — your comment may be first.