Description
Features
Reviews
Special switch, Product range: Special switches, Type reference: T5, STOP function: EMERGENCY STOP function, with red rotary handle and yellow locking ring, Notes: Customer-specific design according to form, Protection class: Front IP65, Design: Built-in, Rated operating power AC-23A, 50 - 60 Hz 400 V: P = 55 kW, Rated continuous current: Iu = 100 A, 1 unit(s), Standards and regulations: IEC/EN 60947.0660, IEC/EN 60204, Load disconnector according to IEC/EN 60947-3
| Property | Value |
| Rated operational power at AC-23, 400 V: | 55 kW |
| Rated continuous current Iu: | 100 A |
| Max. Rated operating voltage Ue at AC: | 690 V |
| Version as EMERGENCY STOP device: | no |
| Protection class (IP), front: | IP65 |
| Connection type main circuit: | Screw connection |
| Device design: | Built-in device, fixed installation technology |
| Design of the actuating element: | Door coupling rotary drive |
| Suitable for floor mounting: | no |
| Conditional rated short-circuit current Iq: | 2 kA |
| Motor drive integrated: | no |
| Suitable for front mounting 4-hole: | yes |
| Version as maintenance/repair switch: | yes |
| Voltage release optional: | no |
| Suitable for front mounting central: | no |
| Suitable for intermediate installation: | no |
| Suitable for distribution board installation: | no |
| Version as main switch: | yes |
| Version as safety switch: | no |
| Motor drive optional: | no |
| Lockable: | yes |
| Version as reversing switch: | no |
| Rated short-time withstand current Icw: | 1.7 kA |
| Color of the actuating element: | red |
| Rated operating voltage: | 690 V |
| Rated operating power at AC-3, 400 V: | 30 kW |
| Switching capacity at 400 V: | 55 kW |
| Rated continuous current at AC-21, 400 V: | 100 A |
| Number of Switch: | 1 |
| Rated continuous current at AC-23, 400 V: | 100 A |
| Protection class (NEMA): | 12 |
Features
HAB
T5-1-SOND*/EA/SVB installation
Manufacturer
HAN
908031
GTIN
2000007417649
Connection type main circuit
Screw connection
Number of switches
1
Designed as main switch
Yes
Designed as an EMERGENCY STOP device
No
Designed as a safety switch
No
Designed as a maintenance/repair switch
Yes
Version as reversing switch
No
Design of the actuating element
Door coupling rotary drive
Conditional rated short-circuit current Iq
2kA
Rated operational power at AC-23, 400 V
55kW
Rated operational power at AC-3, 400 V
30kW
Rated operating voltage
690V
Rated continuous current Iu
100A
Rated continuous current at AC-21, 400 V
100A
Rated continuous current at AC-23, 400 V
100A
Rated short-time withstand current Icw
1.7kA
Color of the actuator
Red
Suitable for floor mounting
No
Suitable for front mounting 4-hole
Yes
Suitable for front mounting Central
No
Suitable for distribution board installation
No
Suitable for intermediate construction
No
Device type
Built-in device Fixed installation technology
Max. rated operating voltage Ue at AC
690V
Motor drive integrated
No
Motor drive optional
No
Switching capacity at 400 V
55kW
Protection class (IP), front
IP65
Protection class (NEMA)
12
Voltage release optional
No
Lockable
Yes
No reviews yet — your comment may be first.
All reviews 0